Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T20CM01263

Parcel: 13711425E


Addresses:

1760 W IRVINGTON RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
04/08/2022 REINFORCED MASONRY PRE-GROUT Approved Approved - final lift for the ramp located NE corner of building, final lift for the ramp at ADA sidewalk and driveway at front of property, all masonry is complete
04/04/2022 REINFORCED MASONRY PRE-GROUT Partial Approval Partial for trash enclosure to top,
1st lift for the ramp located NE corner of building, 1st lift for the ramp at ADA sidewalk and driveway at front of property, okay to grout progress areas
01/31/2022 REINFORCED MASONRY PRE-GROUT Not ready for Inspection NR
08/23/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial approval for top of wall at all 4 stair and elevator towers
08/20/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, stairwell towers 2&3, elevator shafts ok to grout progress areas.
08/19/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, 4th lift for stairways and elevators
08/16/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, 2nd and 3rd lift for stairwells and elevators
08/13/2021 REINFORCED MASONRY PRE-GROUT Not ready for Inspection NR
08/11/2021 REINFORCED MASONRY PRE-GROUT Cancelled Cancelled by Contractor
08/11/2021 REINFORCED MASONRY PRE-GROUT Cancelled Cancelled by Contractor
08/10/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, 1st lift for elevators and stairways.
05/11/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, 2nd lift for stairwells and elevator shafts, lintels in place.
05/06/2021 REINFORCED MASONRY PRE-GROUT Partial Approval Partial, 1st lift for stairwells and elevator shafts.