Permit: T20CM00312

Parcel: 12513068A

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/16/2022 EXT METAL CLIPS/EXT SHEATHING Approved Approved
06/01/2021 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Cowboy section. South east stairwell. Dan’s glass on exterior wall
04/08/2021 EXT METAL CLIPS/EXT SHEATHING Partial Approval PARTIAL BRONCOS SECTION LEVEL 4 SOUTH CORRIDOR #401
03/17/2021 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Vikings Building Level #5 Clip/Nails for Room Units 3417-3424 upper; stairwell #505; shear walls (Viking side only) at Room Units 3417-3418.
03/02/2021 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. South exterior wall shear wall at GL: A/7-14: Vikings/Steelers Building Area; Levels #1-4.
12/29/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Level 4. Densglass, Southeast corner to southwest corner.
12/15/2020 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection
12/02/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Cowboys Broncos area, Level 4. Metal sheer panels installed.
11/18/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Cowboy section, level 4, H2.5 clips and joist hangers. Partial. Green Bay and Cardinals section, level 4, exterior sheathing on south side.
11/13/2020 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection Not ready.
11/10/2020 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection Not ready.
11/06/2020 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection Not ready.
10/29/2020 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection Not ready.
10/16/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Arizona Cardinals section, Level 4, exterior densglass, floor and roof decks.
09/30/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Exterior walls in Arizona section. Levels 1, 2 &3.
09/29/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Level 2 Green Bay building section.
09/28/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Missing screws in densglass. Contractor will contact sub contractor to verify screw pattern.
09/01/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. All columns and one shear wall on the third level of the Broncos area. Within the gridlines of AA-13 to HH-13 and AA-20 to HH-20.
08/27/2020 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection Not ready, not complete.
08/24/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Exterior walls on Cardinal building. From WW-11.5 to W.7 to PP.7 to PP-11.
08/18/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Building #1; Levels #3; 4; parapet and roof area. Ok to waterproof progress areas.
08/04/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Level 2. Exterior framing only within the gridlines of HH-1 to WW-1 and HH-6 to WW-6.
07/30/2020 EXT METAL CLIPS/EXT SHEATHING Partial Approval Partial. Level 1. Exterior framing only within the gridlines of HH-1 to WW-1 and HH-6 to WW-6.