Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2019 | INSP - INITIAL CODE ENFORCMENT | Approved | ||
| 12/20/2019 | INSP - INITIAL CODE ENFORCMENT | Approved | THERE IS FIRE DAMAGE TO THE REAR ADDITION WHICH IS A BEDROOM, THERE IS DAMAGE TO 4X8 AREA OF CEILING DRYWALL AND 6 X7 DRYWALL IN THE WALL. THE 2X6 ROOF RAFTERS HAVE FIRE DAMAGED IN THE EAVE AREA. THE ROOF HAS FIRE DAMAGE ESTIMATE AREA OF 6 X 8. THE ABUTTING ADDITION STORAGE ROOM SHARE A WALL THIS ROOM HAS DAMAGE TO THE EXTERIOR WALL AND ROOF. THESE ROOM ARE NOT CODE COMPLIANT. ELECTRICAL: THE REAR ADDITION HAS MULTIPLE NM CABLES IN THE EXTERIOR OF THE REAR WALL WITH FIRE DAMAGE AND MELTED DEVICES. THE INTERIOR HAS A NM CABLE IN THE DAMAGED DRYWALL AREA. THE ABUTTING STORAGE ROOM HAS A PANEL AND EXPOSED NM CABLES ALSO NOT CODE COMPLIANT. POWER WAS DISCONNECTED BY TEP. PLUMBING: GAS METER WAS PINNED SHUT BY SWG, THE GAS LINE RUN INSIDE OF THE ADDITION'S WALL. MECHANICAL: MILD SMOKE DAMAGE TO THE ENTIRE DWELLING. REMARKS: THIS HOME IS NOW CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS. OWNER WILL SECURE THE HOME. |