Case: T19DV09500
Case Details
Entered Date:
12/20/2019
Applicant:
RIVAS GABRIELA
Description:
house fire requesting building safety
Outstanding Inspections
Case Number: T19DV09500
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV09500
Case Description: EMERGENCY
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2019 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | THERE IS FIRE DAMAGE TO THE REAR ADDITION WHICH IS A BEDROOM, THERE IS DAMAGE TO 4X8 AREA OF CEILING DRYWALL AND 6 X7 DRYWALL IN THE WALL. THE 2X6 ROOF RAFTERS HAVE FIRE DAMAGED IN THE EAVE AREA. THE ROOF HAS FIRE DAMAGE ESTIMATE AREA OF 6 X 8. THE ABUTTING ADDITION STORAGE ROOM SHARE A WALL THIS ROOM HAS DAMAGE TO THE EXTERIOR WALL AND ROOF. THESE ROOM ARE NOT CODE COMPLIANT. ELECTRICAL: THE REAR ADDITION HAS MULTIPLE NM CABLES IN THE EXTERIOR OF THE REAR WALL WITH FIRE DAMAGE AND MELTED DEVICES. THE INTERIOR HAS A NM CABLE IN THE DAMAGED DRYWALL AREA. THE ABUTTING STORAGE ROOM HAS A PANEL AND EXPOSED NM CABLES ALSO NOT CODE COMPLIANT. POWER WAS DISCONNECTED BY TEP. PLUMBING: GAS METER WAS PINNED SHUT BY SWG, THE GAS LINE RUN INSIDE OF THE ADDITION'S WALL. MECHANICAL: MILD SMOKE DAMAGE TO THE ENTIRE DWELLING. REMARKS: THIS HOME IS NOW CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS. OWNER WILL SECURE THE HOME. |
| 12/20/2019 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | |
| 12/23/2019 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL DOCUMENTS IN SIRE,, CLOSE CASE |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T19DV09500
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 12/20/2019 | CONTACTED IN PERSON |
| 12/20/2019 | NOTICE AND ORDER ISSUED |
| 12/20/2019 | VIOLATION CLOSED |
| 12/20/2019 | STRUCTURE SECURED BY ??? |
| 12/20/2019 | CALLBACK |