Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

12/20/2019

Applicant:

RIVAS GABRIELA

Description:

house fire requesting building safety

Outstanding Inspections

Case Number: T19DV09500
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV09500
Case Description: EMERGENCY
Total Completed Inspections - 3
End Date Description Inspector Results Comments
12/20/2019 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THERE IS FIRE DAMAGE TO THE REAR ADDITION WHICH IS A BEDROOM, THERE IS DAMAGE TO 4X8 AREA OF CEILING DRYWALL AND 6 X7 DRYWALL IN THE WALL. THE 2X6 ROOF RAFTERS HAVE FIRE DAMAGED IN THE EAVE AREA. THE ROOF HAS FIRE DAMAGE ESTIMATE AREA OF 6 X 8. THE ABUTTING ADDITION STORAGE ROOM SHARE A WALL THIS ROOM HAS DAMAGE TO THE EXTERIOR WALL AND ROOF. THESE ROOM ARE NOT CODE COMPLIANT. ELECTRICAL: THE REAR ADDITION HAS MULTIPLE NM CABLES IN THE EXTERIOR OF THE REAR WALL WITH FIRE DAMAGE AND MELTED DEVICES. THE INTERIOR HAS A NM CABLE IN THE DAMAGED DRYWALL AREA. THE ABUTTING STORAGE ROOM HAS A PANEL AND EXPOSED NM CABLES ALSO NOT CODE COMPLIANT. POWER WAS DISCONNECTED BY TEP. PLUMBING: GAS METER WAS PINNED SHUT BY SWG, THE GAS LINE RUN INSIDE OF THE ADDITION'S WALL. MECHANICAL: MILD SMOKE DAMAGE TO THE ENTIRE DWELLING. REMARKS: THIS HOME IS NOW CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS. OWNER WILL SECURE THE HOME.
12/20/2019 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved
12/23/2019 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCUMENTS IN SIRE,, CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T19DV09500
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
12/20/2019 CONTACTED IN PERSON
12/20/2019 NOTICE AND ORDER ISSUED
12/20/2019 VIOLATION CLOSED
12/20/2019 STRUCTURE SECURED BY ???
12/20/2019 CALLBACK

Documents

File Name Document Type  
20191220_171836.JPG DOCUMENTS VIEW
20191220_171848.JPG DOCUMENTS VIEW
20191220_171858.JPG DOCUMENTS VIEW
20191220_172127.JPG DOCUMENTS VIEW
20191220_172137.JPG DOCUMENTS VIEW
20191220_172450.JPG DOCUMENTS VIEW
20191220_172504.JPG DOCUMENTS VIEW
20191220_172532.JPG DOCUMENTS VIEW
20191220_172549.JPG DOCUMENTS VIEW
20191220_172620.JPG DOCUMENTS VIEW
20191220_172635.JPG DOCUMENTS VIEW
20191220_172645.JPG DOCUMENTS VIEW
20191220_173111.JPG DOCUMENTS VIEW
20191220_173148.JPG DOCUMENTS VIEW
20191220_173200.JPG DOCUMENTS VIEW
20191220_173208.JPG DOCUMENTS VIEW
20191220_173220.JPG DOCUMENTS VIEW
20191220_180543 (1).JPG DOCUMENTS VIEW
20191220_180543.JPG DOCUMENTS VIEW
DAMAGE REPORT 2019 4572 E 31ST ST.DOC DOCUMENTS VIEW
4572 E 31ST.PDF DOCUMENTS VIEW