Inspection History: PLUMBING - FINAL
Permit Number - T19CM07273
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2019 | PLUMBING - FINAL | Approved | SWG clearance is required. | |
10/09/2019 | PLUMBING - FINAL | Not ready for Inspection | Flue pipe on roof not properly installed, needs to be 3 feet above cooler inlet, provide pan under water heater, sediment Traps at water heater and furnace not properly installed. | |
10/07/2019 | PLUMBING - FINAL | Denied | Gas line below grade covered prior to inspection, roof jack required at all roof penetrations, gas pipe on roof to be blocked up minimum 3 inches, flue pipe at water heater not properly attached, flue pipe to be a minimum 3 feet above cooler inlet , provide access to interior |