Permit: T19CM01829

Parcel: Unknown


Addresses:

6442 E SPEEDWAY BL

Inspection Status: Passed

Inspection History: ENGR Grading Final

Date Description Inspector Results Comments
06/19/2020 ENGR Grading Final DROBERTS Approved Entered by RSALDAT1 - IS APPROVED
02/04/2020 ENGR Grading Final DROBERTS Not ready for Inspection Entered by DMERANZ1 - THIS WAS THE INSPECTION NEEDED FOR TODAY, BUT THE CONTRACTOR POURED THE STRUCTURE BEFORE I INSPECTED THE REBAR. THE HORIZONTAL REBAR IN THE FOOT WAS OK, BUT THE VERTICAL REBAR WAS INCORRECT. THE CONTRACTOR PLACED THE VERTICAL BARS AS #4 AT 48 INCHES ON CENTER AND THEY SHOULD HACE BEEN NO MORE THAN 32 INCHES ON CENTER. I HAVE DIRECTED THE PRIME CONTRACTOR/CAYLOR CONSTRUCTION TO HAVE THE SUBCONTRACTOR DRILL AND DOWL #4 REBAR INTO THE FOOTER AT EVERY LOCATION THAT IS WIDER THA 32 INCHES AND THEN RECALL THE INSPECTION IN PRIOR TO PLACING ANY BLOCKS FOR THE WALL CONSTRUCTION.