Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T18OT01107

Parcel: 11620134B


Addresses:

875 W CUSHING ST


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T18OT01107

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
11/14/2019 SIGN SITE REVIEW Approved
11/09/2019 SIGN SITE REVIEW Continued Brian Wiese checked site for any grade issues in advance that the permit could be released once sewer encroachment resolved.
03/19/2019 SIGN SITE REVIEW Approved Contractor provided Recorded "Public Sewer Easement Encroachment Agreement" document signed by Rio Nuevo, PC Real Estate and Director of PCRWRD. (20190530278, on 2/22/19, 5 pages)
02/06/2019 SIGN SITE REVIEW Continued Update from sign contractor that Pima County Sewer easement and sign placement are still in discussion.
12/28/2018 SIGN SITE REVIEW Continued No further updates received as of 12/28/18 on permission/written agreement to locate monument sign within PC sewer easement.
11/07/2018 SIGN SITE REVIEW Continued Revised engineered drawings received for review.
11/07/2018 SIGN SITE REVIEW Continued Structural has approved the monument sign design.

Staff conducting grade/setback check 11/9 for sign placement in event following matter resolved:

Found sewer easement along Cushing. Sign located withn easement with double caisson footer. Emailed architect, Joel Mesik, inquiring on possible documentation to utilize this easement area for sign placement (pipe may not be near sign). Easement is nearly 32' back from property line on Cushing. Sign is 28' setback from face of street curb of Cushing to leading edge of structure. Awaiting response. Called contractor, Palo Verde Signs, with advisement of situation. If easement agreement allows use, sign permit ready to be released.
10/31/2018 SIGN SITE REVIEW Continued RE: revised proposal - 2 monuments
For: 875 W Cushing Street / Caterpillar
Sign Permit: T18OT01107
Reviewers: H.Thrall (Sign Standards/NEC, OLC)
E. Newcomb (Structural)

1) Separate calcs and drawing into two sheets - data cannot be read nor scanned sufficiently with the amount of information on one sheet. Seal both calcs and engineered drawing.

2) Specify if welding is shop or field. (Field welding requires special inspection.) IBC 2012

3) Specify which bolts are going to be used and the calculations provided to support their use - anchor or high strength. (Note - high-strength bolts require special inspection.) IBC 2012

4) Acknowledged access point signs are being revised and submitted for separate review, and removed from this set of drawings/permit package.

5) Acknowledged dimensioned street frontages now shown on site plan. Acknowledged both monument signs will be out of sight visibility triangles due to their proposed setbacks at 28 and 39 feet from faces of each street curb, respectively. Acknowledged one monument per street front. Acknowledged raised lettering off structure surface in revision.

6) Provide revised application to match sign area on revised drawing set.

Email revisions to Heather.Thrall@tucsonaz.gov

If you need information on special inspection forms or inspectors by company name/person - email Heather.Thrall@tucsonaz.gov for further assistance.
10/30/2018 SIGN SITE REVIEW Continued Contractor submitted revised site plan and engineered monument sign details.
10/24/2018 SIGN SITE REVIEW Continued Design change forthcoming for review. Discussed twice with contractor - sign area and then engineering, base change coming.