Inspection History: FRAMING

Date Description Inspector Results Comments
11/21/2019 FRAMING Approved
11/20/2019 FRAMING Cancelled per phone call with customer.
09/23/2019 FRAMING Not ready for Inspection Should be scheduled with intermediates
08/14/2019 FRAMING Not ready for Inspection Partial inspection of roof framing and exterior walls only at this time. 2x6 rafters that are full length over brick portion are over-spanned per IRC Table R802.4.1(1). 1-Install knee wall to roof below over rafter at existing wall near mid-span. 2-Some pitch cuts are incorrect at ridge; install pressure blocking on both sides of these at the ridge.
Reschedule with intermediates.