Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - UFER
Permit Number - T18CM04589
Inspection Description - ELECTRIC - UFER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/30/2019 | ELECTRIC - UFER | Approved | ||
04/24/2019 | ELECTRIC - UFER | Partial Approval | North LN2 vaporizer pad generator pads East equipment yard |
|
03/06/2019 | ELECTRIC - UFER | Cancelled | ||
01/30/2019 | ELECTRIC - UFER | Partial Approval | Ground ring north of GL 11 from E to F with one ground rod only | |
01/28/2019 | ELECTRIC - UFER | Partial Approval | ETF ground ring east side except under scaffold and from northeast corner 30 feet west OK to cover. | |
01/24/2019 | ELECTRIC - UFER | Partial Approval | Continuation of ground loop East of building GL - A from 2 - 4 only except welds at 2 ground rods | |
08/31/2018 | ELECTRIC - UFER | Partial Approval | ||
08/30/2018 | ELECTRIC - UFER | Partial Approval | ||
08/29/2018 | ELECTRIC - UFER | Partial Approval | 76' X 6'FOOTER GL 8 FROM A-C #8 BARS 16: OC TOP AND BOTTOM COLUMN C/8 WITH GROUND F-5 FOOTER COLUMN B/9 WITH GROUND F-6 FOOTER COLUMN B/10 WITH GROUND F-5 FOOTER COLUMN A/7 WITH GROUND F-5 FOOTER COLUMN A/6 WITH GROUND F-8 FOOTER COLUMN D/4 WITH GROUND F-8 FOOTER COLUMN D/3 WITH GROUND F-4 & F-5 FOOTER COULMN F/2 WITH GROUND 41' X 3' FOOTER WITH WITH F-5 FOOTERS COLUMN G/2 WITH GROUND #8 BARS @ 18" OC TOP AND BOTTOM 36' X 3' FOOTER GL2 FROM C-E 2 EACH F-5 FOOTERS COLUMN C/2 & D/2 WITH GROUNDS SEE HIGHLIGHTED PLAN PENDING SPECIAL INSP. REPORTS |
|
08/27/2018 | ELECTRIC - UFER | Partial Approval | AFTER HOURS APA ACCOUNT $165.00 8-10 AM F-7 FOOTER COLUMN D/8 WITH GROUND F-6 FOOTER COLUMN F/9 WITH GROUND F-6 FOOTER COLUMN K/7 WITH GROUND SEE HIGHLIGHTED AS2.00 PLAN |
|
08/27/2018 | ELECTRIC - UFER | Partial Approval | AFTER HOURS PA ACCOUNT $165.00 F-5 FOOTER COLUMN E/11 F-6 FOOTER COLUMN E/10 F-6 FOOTER COLUMN C/10 F-5 FOOTER COLUMN C/9 F-5 COLUMN E/8 F-5 FOOTER COLUMN G/10.8 F-4 FOOTER COLUMN G/11 F-5 FOOTER COLUMN H/10.8 F-5 FOOTER COLUMN J/10.8 F-4 FOOTER COLUMN J.5/10.8 ALL WITH GROUND |
|
08/23/2018 | ELECTRIC - UFER | Partial Approval | F-5 FOOTERS GL 8/8 & 8/L WITH GROUND F-6 FOOTER GL9/M WITH GROUND F-6 FOOTER GL 7/M WITH GROUND F-7 FOOTERS GL G/7 & G/4 F-6 FOOTERS GL 3/G & 3/F WITH GROUND F-6 FOOTER GL 4/F WITH GROUOND F-7 FOOTER GL 6/F WITH GROUND F-6 FOOTER GL 7/F WITH GROUND F-5 FOOTER GL 8/F WITH GROUND PENDING SPECIAL INSP REPORT SEE HIGHLIGHTED FOUNDATION PLAN |
|
08/22/2018 | ELECTRIC - UFER | Partial Approval | F-6 FOOTER GL H/3 WITH GROUND F-7 FOOTER GL H/4 WITH GROUND F-6 FOOTER GL H/6 WITH GROUND F-6 FOOTER GL H/7 WITH GROUND F-6 FOOTER GL J/4 WITH GROUND F-4 FOOTERS GL'S J/5 & J/6 F-5 FOOTERS GL K/2, K/3 & K/5 F-6 FOOTER'S GL K/6, K/4 WITH GROUND F-7 FOOTERS GL L/2, L/3 & L/5 F-6 FOOTER GL L/4 WITH GROUND F-5 FOOTERS GL M/3, M/4 & M/5 PENDING SPECIAL INSP. REPORT SEE HIGHLIGHTED FOUNDATION PLAN |