Permit: T18CM03773

Parcel: 130170760


Addresses:

4019 E 27TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/19/2019 ELECTRIC - INTERMEDIATE Approved
11/14/2018 ELECTRIC - INTERMEDIATE Partial Approval make sure can lights maintain inch and a half clearance on sides and 3 inches above to combustibles and plastic pipes. Use correct exterior boxes that are designed to hold more than one Romex if using multiple exterior lights.
10/24/2018 ELECTRIC - INTERMEDIATE Correction Required Staple all NM-Romeo in attic at 4’ oncenter.
Install all J-Boxes for exterior wiring for lights.
Calk/Foam al sole and top plate penetrations.