Case: T17DV00541

Parcel: 10714184A


Addresses:

2513 N CASTRO AV #B


Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T17DV00541

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
03/30/2017 INSP - FOLLOW UP CODE ENFORCE Approved SPOKE WITH RICK SALDATE, INFORMED HIM THE TWO FRONT UNITS HAD SERVICE UPGRADES, PERMITS FINALED AND STRUCTURES RE OCCUPIED. EXPLAINED 4 REAR TRAILERS ARE STILL POSTED AND REMAIN VACANT, AND TPD OFFICER HOULD CONTINUES TO MONITOR UNITS. ASKED RICK HOW TO PROCEED, RICK STATED C/E NO LONGER NEEDED TO MONITOR THE CASE TO GO AHEAD AND CLOSE CASE, STATED C/E CAN ALWAYS REOPEN A CASE IF REQUIRED. COMPLIANCE / CLOSE CASE.
03/08/2017 INSP - FOLLOW UP CODE ENFORCE Approved Met with Insprontector Goodman to verify the work to the fron Work is code compliant.
03/08/2017 INSP - FOLLOW UP CODE ENFORCE Approved INSPECTION FOUND SERVICE UPGRADES ADDED TO TWO FRONT UNITS, 2513 AND 2519, PERMITS SECURED AND FINALED, HOLLANDER INSPECTED AND OKED WORK TO BOTH UNITS. ALSO WALKED THE INTERIOR OF BOTH UNITS TO CHECK INTERIOR ELECTRICAL ISSUES. FOUND SHAEFFER ELECTRIC HAD COMPLETELY GONE THRU BOTH UNITS MADE ANY AND ALL CHANGES TO MAKE THE UNITS SAFE.
FOUND TRAILERS REMAINED VACANT.
SPOKE TO MARTIN ROMERO WHO ASKED WE CLOSE THE CASE DUE TO VACANT TRAILERS AND UPGRADED HOUSES AND IF WE FIND THE TRAILERS BREACHED, WE WOULD REOPEN A CASE. COMPLIANCE / CLOSE CASE.
03/07/2017 INSP - FOLLOW UP CODE ENFORCE Approved Met with inspector Goodman. Call the electricians to see what work was done to the interiors. No work to the rear moble units.
02/21/2017 INSP - FOLLOW UP CODE ENFORCE Approved PERMITS WERE SECURED BY SHAEFFER ELECTRIC FOR SERVICE UPGRADES TO THE TWO FRONT UNITS.
02/17/2017 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE WITH RICK HOLLANDER, CHECKED THE EXTERIOR SERVISCE PANEL TO THE TRAILERS, SERVICE PANEL WAS MOUNTED ON A UNSTABLE POLE, ADDED CIRCUITS, UNSAFE WIRING, BROKEN CONDUIT AND JUNCTION BOXES BELOW GROUND. THE SERVICE PANEL ON THE MAIN STRUCTURE HAD BEEN TAPPED INTO AND SYSTEM ALSO UNSAFE. WE WALKED EVERY UNIT INDIVIDUALLY AND FOUND MULTIPLE ELECTRICAL ISSUES IN AL UNITS, ALL HAD TWO WIRE SYSTEMS, THREE WIRE OUTLETS AND MOST OUTLETS OVERLOADED. RICK FELT THE SYSTEM WAS UNSAFE, SPOKE TO RICK SALDATE AND IT WAS DETERMINED TO POST UNIT UNIT TO OCCUPY. TPD WAS CONTACTED AND ARRIVED ON SITE TO KEEP THE PEACE. INFORMED OCCUPANTS OF THE SITUATION AND INFORMED THEM THEY WOULD NEED TO FIND SAFE HOUSING. RED CROSS ALSO SHOEWED UP TO HELP OCCUPANTS. EVENTUALLY SHAEFFER ELCTRICAL WAS CONTACTED BY OWNER AND SHOWED TO LOOK AT THE SITUATION. J SHAEFFFER STATED THEY COULD EASILY RESTORE POWER TO THE TWO FRONT HOUSES. BUT STATED RESTORING POWER TO THE TRAILERS WOULD BE A STRETCH AND NOT LIKELY.