Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T17CM09029

Parcel: 121100430


Addresses:

4861 E HAMPTON ST

Inspection Status: Passed

Inspection History: COT - LCBU - Framing

Date Description Inspector Results Comments
07/11/2018 COT - LCBU - Framing TVALENC1 Approved Entered by TVALENC1 - IVRS - Inspection :*
07/06/2018 COT - LCBU - Framing dflores2 Denied Entered by DFLORES2 - LOOSE BOLTS ON TOE PLATE MISSING NAILS ON SHEER WALL AT ENTRANCE
06/20/2018 COT - LCBU - Framing GWest Correction Required Entered by GWEST2 - Framing is not complete. Window changes or window elimination. Light and ventilation is required for living areas at 8% Light and 4% vVentilation. Make sure your egress window rough opening will comly with egress window standards. Anchor bolting and shot pins for interior and exterior wall shall be installed for framing inspection. Install any missing drywall backing at top plate. Install all missing nails required at Rafter/Joist hangeres. Bolt and attach the new wood framed addition walls to the existing masonry structure with approved attachment hardware and methods. Finish all previous corrections. Recall this inspection once again when all corrections have been made and the structure is ready for re-inspection. There may be other/further corrections upon re-inspection
06/14/2018 COT - LCBU - Framing DFLORES2 Denied Entered by DFLORES2 - 1 TAKE OUT SHINNERS ON SHEAR WALL AND RE NAIL WALL CORRECTLY ROOF PEREMETER NEEDS STAPLES EVERY 4" PER CODE