Permit: T17CM08953

Parcel: 11620134B


Addresses:

875 W CUSHING ST


Inspection Status: Passed

Inspection History: COT - HCBU - Interior Shear Bracing 

Permit Number - T17CM08953

Inspection Description - COT - HCBU - Interior Shear Bracing 

Inspection Status - Passed

Date Description Inspector Results Comments
02/28/2019 COT - HCBU - Interior Shear Bracing  RCAMACHO Approved Entered by CBELL1 -
02/06/2019 COT - HCBU - Interior Shear Bracing  TVALENCIA Partial Approval Entered by CBELL1 - 1- Okay to sheet rock one side of walls and ceilings in rooms 1012 & 1012 only.
02/05/2019 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CBELL1 - Stairwell number two only
01/31/2019 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CBELL1 - GL 9-11 from A-C level 1
01/23/2019 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CBELL1 - Clouds GL A-C from 3 - 12
12/17/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CBELL1 - level one Gridline 1-3 from A-C
12/03/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CBELL1 - Stairwell 3 and shipping and receiving only
10/30/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CBELL1 - Level 2 GL 8 -14 only
10/12/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CBELL1 - Level three except core
10/02/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CMURPHY1 - Rooms 3069, 1118, 1068 & 1010
09/28/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CMURPHY1 - 1 side only GL 13 - 14 from A-C
09/13/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CMURPHY1 - F-1 & F-2 footers Garage GL MG -FG from 1G- 6G 28 Footings total See highlighted S1.1.0 plan Completion of east exterior wall only SES uaerd 1st lift only 2 x 2" & 1 x 1" from loading and receiving to trench C and to mech yard Trench C to mech uard 5 x 3 1/2 " * 2 x 1"
09/12/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by CMURPHY1 - Exterior west walls only ok to cover
08/07/2018 COT - HCBU - Interior Shear Bracing  RCAMACHO Partial Approval Entered by RCAMACH1 - EXTERIOR EAST WALL 2ND LIFT TO TOP OUT ONLY