Permit: T17CM08953

Parcel: 11620134B


Addresses:

875 W CUSHING ST


Inspection Status: Passed

Inspection History: COT - HCPL - Plumbing Intermediate 

Permit Number - T17CM08953

Inspection Description - COT - HCPL - Plumbing Intermediate 

Inspection Status - Passed

Date Description Inspector Results Comments
02/28/2019 COT - HCPL - Plumbing Intermediate  RCAMACHO Approved Entered by CBELL1 -
02/22/2019 COT - HCPL - Plumbing Intermediate  DQUINN Partial Approval Entered by CBELL1 - Lobby restrooms plumbing complete. Micro market 1084 sinks ok. Fitness center restrooms in wall plumbing ok to cover. Janitor closets 1025, 1090 1104 - water heaters ok.
02/21/2019 COT - HCPL - Plumbing Intermediate  BSTEVENS Partial Approval Entered by CBELL1 - Above ceiling in rooms 1081, 1028, 1078, 1087, 1088 ok to cover
12/21/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CBELL1 - 100 pound test hydronic chillers only OK to insulate central plant
12/20/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CBELL1 - level one wudu rooms 1026 & 1027
12/07/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CBELL1 - Entire copper system potable water test OK to insulate Level 1 dwv except fitness center
11/20/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CBELL1 - Lobby restrooms 2 Galley okay to insulate
11/14/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CBELL1 - Rooms 1002 & 1097
11/07/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by VFLORES1 - Level 1 bathroom okay to insulate
10/23/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CBELL1 - 200 lb test 4 " yard water line
10/19/2018 COT - HCPL - Plumbing Intermediate  ESTEVENS Partial Approval Entered by CBELL1 - Inspected waterline, not under test
10/18/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Not ready for Inspection Entered by CBELL1 -
10/01/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CMURPHY1 - Entire 2nd floor potable water and dwv
09/26/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CMURPHY1 - 3/4" copper condensate line to exterior of shaft 3 2 x 2" sumpnpump risers shaft 3
09/21/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Partial Approval Entered by CMURPHY1 - Potable copper water 2nd & 3rd floor core bathrooms to hub lounges and mothers room sink ok to insulate. DWV 3rd floor same areas
09/14/2018 COT - HCPL - Plumbing Intermediate  RCAMACHO Not ready for Inspection Entered by CMURPHY1 - Tes call center room 3597 Tes Tech Lab room 3096 Tes remote Moon Room 3095 Tes War Room 3094 open offices rooms 3091 and 3093 Mech yard only No test Shaft 1 condensate line only Mechanical shaft number 1 and 3 complete shaft number 2 except exhaust all hard duct GL 10 to 14 from A to C okay to insulate