Inspection Status: Passed
Inspection History: COT - HCBU - Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 02/15/2019 |
COT - HCBU - Framing |
RCAMACHO |
Approved |
Entered by CBELL1 - |
| 02/08/2019 |
COT - HCBU - Framing |
BSTEVENS |
Not ready for Inspection |
Entered by CBELL1 - Recall these inspections |
| 02/05/2019 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - Fitness center only |
| 01/16/2019 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - Hard lids 1116, 1113, 1112, 1105, 1106 and 1103
Clouds GL A-C from 6-8
Rooms1062, 1074- 1079 |
| 12/17/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - level one Gridline 3 to 5 from A-C three out of four clouds only |
| 12/07/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - Soffitt level 1 lobby only |
| 12/05/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - Level 1 Gridline 1 -3 from A-C provide proper bracing lobby soffit |
| 11/20/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - stairwell 3 all levels exterior walls only |
| 11/05/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - Shipping and receiving area only |
| 10/17/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CBELL1 - Level 2 except west rooms walls |
| 10/04/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CMURPHY1 - Stairwell 1 furrouts at stairs and landings except bolts at level 1 landing over exit door |
| 09/28/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CMURPHY1 - Lobby levels 1 & 2
Furrout ext. Wall GL 1 from A-B
Level 3 GL 4- 11from A-C |
| 09/26/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CMURPHY1 - Levels 1,2&3 core restroom walls only |
| 09/17/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CMURPHY1 - TES CALL CTR ROOM 3097
Elevator pit per detail 117 see rfi 281 10" oc each way top and bottom
Rooms 3091, 3093, 3094, 3095, 3096 & 3097
GL A-C from 11-14 LEVEL 3
|
| 09/14/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CMURPHY1 - Exterior west patio wall GL 4 from A-C |
| 09/13/2018 |
COT - HCBU - Framing |
RCAMACHO |
Not ready for Inspection |
Entered by CMURPHY1 - F-1 & F-2 footers Garage GL MG -FG from 1G- 6G 28 Footings total
See highlighted S1.1.0 plan
Completion of east exterior wall only
SES uaerd 1st lift only
2 x 2" & 1 x 1" from loading and receiving to trench C and to mech yard
Trench C to mech uard 5 x 3 1/2 " * 2 x 1"
|
| 09/05/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by CMURPHY1 - EXTERIOR WALLS GL1&2 WRST END ONLY |
| 08/17/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by RCAMACH1 - GL A FROM 10-14 EXTERIOR WALLS ONLY WITH EXTERIOR SOFFITS |
| 08/07/2018 |
COT - HCBU - Framing |
RCAMACHO |
Partial Approval |
Entered by RCAMACH1 - SOUTH WALL 2ND LIFT TO TOP OUT EXCEPT GL 4-5 WEST OF CORE |
| 07/06/2018 |
COT - HCBU - Framing |
RCAMACHO |
Denied |
Entered by RCAMACH1 - PER VSC DETAIL 16/D2 NO MORE THAN 1" MAX GAP BETWEEN STUD AND BUILDING
GL A FROM 4-11 ONLY |