Permit: T17CM08410

Parcel: 125030100


Addresses:

3030 E 4TH ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/29/2018 BUILDING - FINAL Approved IVRS - Inspection :*
06/21/2018 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL SEAL THE GAS PENETRATION AT THE EAST EXTERIOR WALL.
2- SHALL CUT DOWN TO SUB GRADE AND PROVIDE A GAS TIGHT FEMALE COUPLING WITH PLUG FOR THE TWO WAY CLEAN OUT.
3- SHALL SECURE THE DISHWASHER DRAIN HOSE AS HIGH AS POSSIBLE TO THE BOTTOM OF THE COUNTER TOP.
4- SHALL PROVIDE WATER HAMMER ARRESTORS FOR THE DISHWASHER AND ICE MAKER WATER SUPPLYS.
5- SHALL SHALL PROVIDE A FIXED METHOD FOR KEEPING THE FIREPLACE FLU DAMPER TO BE FIXED IN A OPEN POSITION.
6- SHALL PROVIDE VACUUM BREAKERS ON ALL HOSE BIBS.
INSPECTION STOP!


*
06/20/2018 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE ACCESS AT THE TIME OF INSPECTION REQUEST. DOORS LOCKED.


*