| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2018 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/26/2018 | FRAMING | Denied | 1- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED FOAM OR CAULK. 2- SHALL SEAL AROUND THE ENTIRE BOTTOM PLATE. 3- SHALL SEAL ALL STUCCO MESH PENETRATIONS. 4- SHALL PROVIDE 2 TIMES THE PIPE DIAMETER MINIMUM TRAP ARM DISTANCE FOR THE WASHING MACHINE . 5- SHALL SET AND SECURE THE CLOSET RINGS TO FLOOR. 6- SHALL REMOVE THE P-TAPE ON THE 3 INCH VTR AND PROVIDE AN APPROVED METHOD OF STRAPPING. |
|
| 03/21/2018 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999 2- REFERENCE LOCKS,HOLD AND NOTICES AND PROVIDE PROOF OF THE REQUIRED BOND. * |
|
| 11/21/2017 | FRAMING | Prior to Intermediates | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION |