Permit: T17CM08155

Parcel: 133250540


Addresses:

8540 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/02/2018 FRAMING Approved IVRS - Inspection :*
03/26/2018 FRAMING Denied 1- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED FOAM OR CAULK.
2- SHALL SEAL AROUND THE ENTIRE BOTTOM PLATE.
3- SHALL SEAL ALL STUCCO MESH PENETRATIONS.
4- SHALL PROVIDE 2 TIMES THE PIPE DIAMETER MINIMUM TRAP ARM DISTANCE FOR THE WASHING MACHINE .
5- SHALL SET AND SECURE THE CLOSET RINGS TO FLOOR.
6- SHALL REMOVE THE P-TAPE ON THE 3 INCH VTR AND PROVIDE AN APPROVED METHOD OF STRAPPING.
03/21/2018 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999
2- REFERENCE LOCKS,HOLD AND NOTICES AND PROVIDE PROOF OF THE REQUIRED BOND.


*
11/21/2017 FRAMING Prior to Intermediates ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION