Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T17CM02636
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2019 | FRAMING | Approved | ||
12/13/2018 | FRAMING | Partial Approval | galley room J0 510 janitor closet J0 520 and water closet room J0 530 OK to insulate water lines | |
12/13/2018 | FRAMING | Partial Approval | Galley room J0510, janitors closet J0520 & water closet room J0530 Ok to insulate hot water lines |
|
12/04/2018 | FRAMING | Partial Approval | Conference Room H0525 | |
11/29/2018 | FRAMING | Partial Approval | Data room, vestibule, wing wall at LSV lab ok, JO510 and JO510 ok | |
11/09/2018 | FRAMING | Partial Approval | Area A vestibule L0503B | |
10/30/2018 | FRAMING | Partial Approval | 10" high walls rooms J0530,J0540 & J0510 | |
10/17/2018 | FRAMING | Partial Approval | 10" high wall GL J.5 from 5-8 only | |
10/02/2018 | FRAMING | Partial Approval | 10" wall GL 4 from F - G only | |
09/21/2018 | FRAMING | Partial Approval | GL-C-D grom 8.5 -9 high wall GL 5 from G-F highwall |
|
09/20/2018 | FRAMING | Partial Approval | Pony wall high wall above GL - F from 7 - 8 | |
09/19/2018 | FRAMING | Partial Approval | -GL C FROM 8.5 TO 9 HIGH WALL -GL C.5 FROM 8.5 TO 8' SHORT OF 9 |
|
09/17/2018 | FRAMING | Partial Approval | 2 x 6 wall with soffits GL -F from 8-9 LN2 tank pad and both vaporizer pads see highlighted S1.1 plan sheetrock 1st layer GL 8 from D-F both sides of wall. Fire caulk west end only |
|
09/13/2018 | FRAMING | Partial Approval | High wall GL 5 from H-J Sh3GL F from 7-8 |
|
09/12/2018 | FRAMING | Partial Approval | Soffitt GL 8 from F - G only West tank pad per detail 3/s1.2 see rfi 330 |
|
09/11/2018 | FRAMING | Not ready for Inspection | ||
09/10/2018 | FRAMING | Partial Approval | GL F from 7 - 8 furrout at beam | |
09/07/2018 | FRAMING | Partial Approval | Popout GL 8 from G-F only 2 x 6wall @ 16"oc GL Q from 5-8 |
|
09/05/2018 | FRAMING | Partial Approval | 2 X 6 WALL 12 " OC GL F FROM 7-8 | |
08/31/2018 | FRAMING | Partial Approval | room p 0 500 only | |
08/30/2018 | FRAMING | Partial Approval | screws at Ledger's room p05 200 Grid line 8 from G to F 12 inch on Center 2 x 6 wall |
|
08/29/2018 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
08/22/2018 | FRAMING | Partial Approval | IVRS - Inspection :* ROOMS P0520 & P0510 PROVIDE BRACING |
|
08/15/2018 | FRAMING | Partial Approval | entry way hall ok | |
08/10/2018 | FRAMING | Partial Approval | IVRS - Inspection :* NORTH CORRIDOR B WALL F0400 AT IT CLOSETS ONLY |
|
08/09/2018 | FRAMING | Partial Approval | ROOMS C0703, C0702,C0704 & C0705 ONLY | |
08/06/2018 | FRAMING | Partial Approval | GL7.5 FROM C-D X-RAY ROOM C0701 NORTH AND EAST WALL ROOM C0705 MACHINE SHOP ROOM A0600 |
|
08/01/2018 | FRAMING | Partial Approval | IVRS - Inspection :* GL F FROM 5-6 ONLY GL 5 FROM G-J 1ST LIFT ONLY |
|
07/31/2018 | FRAMING | Partial Approval | VESTIBULE ROOM E0600 3/4" PLYWOODFIRE RETARDANT OK TO PAINT I SIDE PRIOR TO INSTALL GL 5 FROM J-K 10" WALL FLOOR TO ROOF DECK ROOM C0701 AREA A |
|
07/27/2018 | FRAMING | Partial Approval | SOFFITES IN ROOM B0600 ONLY | |
07/26/2018 | FRAMING | Partial Approval | TOP OUT WALL GL F FROM 2-4 & 6-7 ONLYH | |
07/25/2018 | FRAMING | Partial Approval | 6" NORTH WALL ROOM P0300 ONLY | |
07/24/2018 | FRAMING | Partial Approval | 10 " FIRE WALL GL 5 FROM L-M 2ND LIFT HIGH SECTION TO ROOF DECK 6" CORRIDOR WALL GL 4 FROM G-H |
|
07/20/2018 | FRAMING | Partial Approval | popout at C0600, wall at CL 4 @ H thru F | |
07/17/2018 | FRAMING | Partial Approval | RISER ROOM D0105 PARTITION WALL E0600 & E0700 FURROUT SOUTH WALL ROOM B0600 |
|
07/16/2018 | FRAMING | Partial Approval | VESTIBULE 9 ONLY | |
07/12/2018 | FRAMING | Partial Approval | demising wall at main elec. room ok, and rooms 420 and 430 | |
07/03/2018 | FRAMING | Partial Approval | IVRS - Inspection :*COMPUTER ROOMS ONLY ROOMS C0300, C0200, C0150, C0105, E0155 & E0305 | |
06/29/2018 | FRAMING | Partial Approval | IVRS - Inspection :* 12" WALL 1ST AMD 2ND FLOOR GL N4-M-4 ONLY |
|
06/25/2018 | FRAMING | Not ready for Inspection | ||
06/21/2018 | FRAMING | Partial Approval | 10" WALL GL 4 FROM N-P UP TO 2ND LEVEL ONLY | |
06/19/2018 | FRAMING | Partial Approval | REST ROOMS A0730, A0720, CORRIDOR A0803 & WELLNESS ROOM A0806 | |
05/29/2018 | FRAMING | Partial Approval | F1-7.1 | |
05/14/2018 | FRAMING | Partial Approval | GRID LINE F6-5.1 | |
05/02/2018 | FRAMING | Partial Approval | GRID LINES E1-4, E3.1-2.1 | |
04/20/2018 | FRAMING | Partial Approval | GRID LINE 4 F-C D 1-4 | |
04/16/2018 | FRAMING | Partial Approval | GRID LINE 4C-D, E7-E6, E-F5.1 | |
03/23/2018 | FRAMING | Partial Approval | LAB AND CONFERENCE ROOMS 1ST FLOOR |