Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
Permit Number - T15OT01071
Inspection Description - SIGN SITE REVIEW
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/24/2015 | SIGN SITE REVIEW | Approved | PERMIT READY TO PAY FOR & PICK UP | |
08/14/2015 | SIGN SITE REVIEW | Denied | FARMERS INSURANCE T15OT01071 REVSION: NA/ORGINAL RECEIVED: 8/11/15 REVIEWED: 8/14/15 by Sign Permit Team APPLICATION & DRAWING DENIED. A revision is required as per Sign Code 3-16. Revisions required include: Drawings: Four PAGES have been submitted. Number each page ex.(PAGE 1 OF 4) Page 1: The information required on Page 1 (sign A) of the drawing includes a.Measurements of sign width & length in "decimal feet" (ex. 2.17') to match application. Page 2: The information required on Page 2 of the drawing includes a.Must note page number and number of pages submitted. (ex. Page 2 of 4) b.Elevation photo must include the following i."Over all height" of the top of SIGN in "decimal feet" (ex. OAH 16.8') to match application ii.Direction that the elevation faces (ex. NORTH ELEVATION) iii.the scale used (ex. SCALE 1/4"=1') iv.the frontage length of the suite must be shown. to match application v.before installation photo needed Page 3: Must note page number and number of pages submitted. (ex. Page 3 of 4) a.indicate what the wall is made of. b.indicate size, & length of screws. Page 4: Must note page number and number of pages submitted. (ex. Page 4 of 4) a.wrong location of suite shown on location map. b.add north direction arrow |