Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T15DV03415

Parcel: 130021120


Addresses:

2932 E 26TH ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
05/08/2015 INSP - INITIAL CODE ENFORCMENT Approved THERE IS A 20 FOOT BY 30 FOOT WOOD FRAMED RAMADA BUILT WITH OUT PERMITS AND ZONING APPROVAL. THIS STRUCTURE ABUTS THE MAIN DWELLING UNIT. A STOP WORK ORDER WAS ISSUED SITE.

THE RAMADA HAS 6 POSTS THAT ARE 4'X8'X16'. THE MAKE UP OF THE BEAMS ARE (2) 2"X12" WITH ½ OSB IN BETWEEN THAT ARE BEARING THE ROOF LOAD A DISTANCE OF 16 FEET BETWEEN POSTS. THE RAFTERS ARE 2X8 SPANNED AT 24 OC,.THE RAFTERS ARE BEARING BETWEEN THE BEAM AND THE RIDGE A DISTANCE OF 13.5 FEET ON THE EAST SIDE. THE RAFTERS ARE BEARING BETWEEN THE BEAM AND THE RIDGE A DISTANCE OF 17 FEET ON THE WEST SIDE. THE ROOF IS SHEATH WITH ½ OSB AND COVERED WITH ROOFING PAPER.