Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL
Address:

Entered Date:

05/06/2015

Applicant:

JOSE NICOLAS NAVA

Description:

WORK WITHOUT PERMITS - REAR STRUCTURE

Case Violations

Case Number: T15DV03415
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 1
Violation Date Code Statue
07/08/2015 T.C. Ch. 16, Sec. 16-14. Dilapidated structures; vacant and unsecured structures; buildings and structures constituting a nuisance. (a) Dilapidated structures. Buildings or structures that are so deteriorated, damaged, dilapidated, or in need of repair so as to present a threat to the health, safety and welfare of the community constitute a nuisance and shall be abated by repair, rehabilitation or demolition as provided in Article VI of this chapter.

Outstanding Inspections

Case Number: T15DV03415
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
10/16/2015 NPO - WORK WITHOUT PERMIT VALDEZ Extension granted

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV03415
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/08/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THERE IS A 20 FOOT BY 30 FOOT WOOD FRAMED RAMADA BUILT WITH OUT PERMITS AND ZONING APPROVAL. THIS STRUCTURE ABUTS THE MAIN DWELLING UNIT. A STOP WORK ORDER WAS ISSUED SITE. THE RAMADA HAS 6 POSTS THAT ARE 4'X8'X16'. THE MAKE UP OF THE BEAMS ARE (2) 2"X12" WITH ½ OSB IN BETWEEN THAT ARE BEARING THE ROOF LOAD A DISTANCE OF 16 FEET BETWEEN POSTS. THE RAFTERS ARE 2X8 SPANNED AT 24 OC,.THE RAFTERS ARE BEARING BETWEEN THE BEAM AND THE RIDGE A DISTANCE OF 13.5 FEET ON THE EAST SIDE. THE RAFTERS ARE BEARING BETWEEN THE BEAM AND THE RIDGE A DISTANCE OF 17 FEET ON THE WEST SIDE. THE ROOF IS SHEATH WITH ½ OSB AND COVERED WITH ROOFING PAPER.
10/16/2015 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT T15CM04880 ISSUED AND EXPIRES ON 2-28-2016

Outstanding Case Activity Conditions

Date Name Approved
07/08/2015 TC CHAPTER 16 SEC 16-65 ABATEMENT BY DEMOLITION SHALL BE ORDERED ONLY WHERE REPAIR OF THE STRUCTURE IS UNREASONABLE OR IMPRACTICABLE, AND DEMOLITION AND REMOVAL OF A STRUCTURE OR BUILDING IS NECESSARY TO CORRECT AND ABATE A VIOLATION. ANY ACTION INVOLVING THE DEMOLITION OF A BUILDING OR STRUCTURE SHALL BE COMMENCED BY ISSUING A NOTICE OF VIOLATION TO THE OWNER AND ANY RESPONSIBLE PARTIES IN ACCORDANCE WITH THE PROVISIONS OF SECTION 16-45. Not Approved

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T15DV03415
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
07/06/2015 CONTACTED BY PHONE
05/08/2015 CONTACTED IN PERSON
07/17/2015 CONTACTED BY MAILING
05/08/2015 STOP WORK ORDER ISSUED
07/17/2015 NOTICE OF VIOLATION ISSUED
08/09/2016 VIOLATION CLOSED

Documents

File Name Document Type  
2932 E 26TH ST.PDF DOCUMENTS VIEW
NOV T15DV03415.PDF DOCUMENTS VIEW