Case: T15DV03364

Parcel: 130180020


Addresses:

4100 E 29TH ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T15DV03364

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
05/02/2015 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, FOUND UPON ARRIVAL THAT TFD HAD ALREADY LEFT THE SCENCE, MET WITH OWNER ANN BOYCE WHO STATED TFD HAD BEEN UP ON THE ROOF AND FOUND COOLER ELECTRICAL CONNECTIONS PULLED APART, AS WELL AS THE PLUMBING CONNECTIONS, AND AT THAT POINT ANN BOYCE CALLED A ELECTRICIAN TO CHECK ALL CONNECTIONS FOR SAFETY PURPOSES. ANN HAD ALSO CONTACTED INSURANCE COMPANY WHO CONTACTED AMERICAN TECHNOLIGIES INC. AND SENT OUT REP BRANT ANDERSON WHO STATED THEY DO COMPLETE COMMERCIAL RESTORATON MANAGEMENT. BRANT CONTACTED SERVICE MASTER WHO CAME OUT TO SECURE DAMAGED WINDOWS AND TEMPORARILY COVER PORTONS OF EXPOSED ROOF. MY INSPECTION OF BUILDING #7 FOUND THE FOLLOWING:
> LARGE SECTION OF 3-PLY BUILT UP ROOF REMOVED AND BLOWN OFF THE ROOF. UNDER THE TOP LAYER I FOUND 2 MORE ROOFS (COVERINGS) FOR A TOTAL OF 3 ROOFS. MANUFACTURERS STATE NO MORE THAN 2 LAYERS OF ROOF SHOULD BE ALLOWED ON THE ROOF DUE TO LOAD AND STRESS PLACED UPON THE ROOF FRAMING SYSTEM.
> FOUND ONE COOLER MISSING, ORIGINALLY THOUGHT COOLER WAS BLOWN OFF IN MICRO BURST BUT UNSURE.
>ALL ELECTRICAL AND OR PLUMBING CONNECTIONS WERE IMPROPERLY COMPLETED OR RIPPED OUT BY THE MICRO BURST.
>FOUND PLUMBING VENT PIPES, MECHANICAL VENT PIPES, ROOF JACKS AND TEMINATION CAPS REMOVED OF BROKEN BY THE STORM.