Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date |
Description |
Inspector |
Results |
Comments |
| 03/27/2015 |
INSP - INITIAL CODE ENFORCMENT |
|
Approved |
Did meet with the tenants and able to do an inspection. The front door is loose on the hinges and draging on the floor, the door is not sealed for weatherazition, cooler has electrical on extension cord and dry rotted, not able to get to the water when required, roof has holes and covered with old sinks, exhaust fan vent for the bathroom has a pot over the opening instead of a T-top and blocking the air to vent, kitchen sink P-trap has a hole in the flex pipe and leaking water and gases, electrical panel in the kitchen has electrical tape covering openings where lacking a breaker instead of proper cover plates, cracks in the ceramic tile flooring on the kitchen and dinning room, GFCI not working in kitchen by switch and has open ground by the refrigerator, broken cabinets, roaches, globes lacking through out, windows painted shut or has screws, bathroom sink loose, toilet loose, escutcheon missing in the tug and shower including the overflow for the tub, has a added light in the hallway with exposed wiring on the north side, middle bedroom has hole in the ceiling where the roof leaks and the drywall has fallen, the baseboard heater has been removed and standing against a wall with the wiring exposed and taped, lacking smoke detectors, broken windows, furnace has been yellow tagged by SWG and not able to get to the water heater or the gas meter due to blocked with storage or trash and debris, No gas can be turned on until gas line checked or the appliance checked, lacking door knobs on the interior doors, front room has an portable heater and baseboard heater not working. Did call the owner and went over the issues that needed to be done with-in 24 hours of the smoke detectors, the windows made able to open, the cooler made operable, plumbing issues in the kitchen and bathroom where leaking, broken glass in the windows. Will do N.O.V. RV. |
| 03/26/2015 |
INSP - INITIAL CODE ENFORCMENT |
|
Approved |
No one home and tried to call the tenant and left a message. Will wait for the call back to check the unit. RV. |