Permit: T15CM05483

Parcel: 13321074A


Addresses:

6317 E BROADWAY BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T15CM05483

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
11/19/2015 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
11/13/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11/13/2015 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/06/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/17/2015 REINFORCED MASONRY PRE-GROUT Partial Approval ALL WALLS TAPPED OUT EXCEPT FOR 1/ B.5-B.75 INTERIOR ACCESS
09/14/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/11/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/10/2015 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/09/2015 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/08/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* PARTIAL CMU WALLS AT 16'-20' GL: E/5-5.5 5 / DE; 1/C-B.25;1/B-A;;12,-16,GL:A/3.25-3.75 OK TO GROUT PROGRESS
09/07/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/03/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/03/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 16' - 20'; GL: A/4.5-5 - OK TO GROUT PROGRESS AREA
09/02/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/02/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 12'-16' - ALL WALLS EXCEPT SOUTH WALL, MAIN ENTRY AREA - OK TO GROUT PROGRESS
09/01/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/01/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 8'-12' GL: A/1-3; 1/A-C.5; C.5/1-2; D/2.5-5; 5/D-E - OK TO GROUT PROGRESS AREAS
08/28/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/28/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 4'-8'; GL: 5/D-E 8'-12' GL: E/5-6; 12'-16' GL: 6/E-A; A/4.5-5 - OK TO GROUT PROGRESS AREA
08/27/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/27/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 8'-12'; A/4-5 EAST WALL - OK TO GROUT PROGRESS AREAS
08/26/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/26/2015 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND LIFT AT 4'-8' GL: 5-5.5/A-E - OK TO GROUT PROGRESS AREA
08/25/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/25/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AND STEM WALL AT GL: D/2.5-5; 5/D-E; E/5-6; STEM WALL: D/3.25-6
08/24/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/24/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 0"-48" AFFE GL: 6/A-E, A/1-5, 1/A-C.5, C.5-D/1-2, D/2-3.5 - OK TO GROUT PROGRESS AREAS