Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T15CM05483
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/19/2015 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
11/13/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
11/13/2015 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
11/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL WALLS TAPPED OUT EXCEPT FOR 1/ B.5-B.75 INTERIOR ACCESS | |
09/14/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/11/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/10/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/09/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/08/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL CMU WALLS AT 16'-20' GL: E/5-5.5 5 / DE; 1/C-B.25;1/B-A;;12,-16,GL:A/3.25-3.75 OK TO GROUT PROGRESS | |
09/07/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/03/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/03/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALL AT 16' - 20'; GL: A/4.5-5 - OK TO GROUT PROGRESS AREA | |
09/02/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/02/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 12'-16' - ALL WALLS EXCEPT SOUTH WALL, MAIN ENTRY AREA - OK TO GROUT PROGRESS | |
09/01/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/01/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 8'-12' GL: A/1-3; 1/A-C.5; C.5/1-2; D/2.5-5; 5/D-E - OK TO GROUT PROGRESS AREAS | |
08/28/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/28/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALL AT 4'-8'; GL: 5/D-E 8'-12' GL: E/5-6; 12'-16' GL: 6/E-A; A/4.5-5 - OK TO GROUT PROGRESS AREA | |
08/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 8'-12'; A/4-5 EAST WALL - OK TO GROUT PROGRESS AREAS | |
08/26/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/26/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2ND LIFT AT 4'-8' GL: 5-5.5/A-E - OK TO GROUT PROGRESS AREA | |
08/25/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/25/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AND STEM WALL AT GL: D/2.5-5; 5/D-E; E/5-6; STEM WALL: D/3.25-6 | |
08/24/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/24/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 0"-48" AFFE GL: 6/A-E, A/1-5, 1/A-C.5, C.5-D/1-2, D/2-3.5 - OK TO GROUT PROGRESS AREAS |