Case: T14DV04582

Parcel: 107130610


Addresses:

2720 N FRITZ DR

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
01/28/2015 INSP - FOLLOW UP CODE ENFORCE Approved Followup to check ceiling in bathroom; repaired with minimum of workmanship. Case will be closed.
12/04/2014 INSP - FOLLOW UP CODE ENFORCE Approved Inspection of unit 1 scheduled by owner; baseboard heaters and kitchen conduit in cabinets repaired under permit T14CM08072; plug-in ventilation fan installed like for like in bathroom; cover on subpanel; storage ok; window in bedroom #1 still lacks glass, owner wants to enclose which requires permit (he will decide whether to reinstall glass at this point); unit ok to occupy.
10/08/2014 INSP - FOLLOW UP CODE ENFORCE Approved Site inspection at location with owner. Unit 1 is now vacant; went over previous code violations from T14DV03488 and new ones observed at 10/02/14 inspection; subpanel dead front in kitchen was installed, but knockout openings need cover; gfci outlet confirmed operable; all other violations still present. Owner advised and unit re-posted. We were not allowed entry into unit 2 of the duplex which owner claimed to be vacant; unit 3 remains vacant with no electrical service.
10/02/2014 INSP - FOLLOW UP CODE ENFORCE Approved Exterior site inspection of property and interior minimum housing inspection of Unit 1 at the request of tenants who have been occupying the unit Since Sept. Note: this unit, along with unit 2 and 3 was previously condemned and required scheduled inspection with owner prior to release of condemnation, which did not occur. Confirmed upgrade under finaled permit T14CM04934 for units 1 & 2 only; service to unit 3 was not included and removed. Unable to access Unit 2 for minimum housing interior inspection. Interior inspection of unit one showed no compliance on previous violation of bathroom ventilation (no mechanical or manual via window); bathroom outlet lacks cover, switch to bathroom in hallway lacks switch but has cover; GFCI outlet with switch in kitchen has operable switch for light, but outlet is not engergized; subpanel in kitchen lacks dead front and cover. baseboard heaters in both bedrooms are lacking covers, are damaged, and do not have grounding wired correctly; original gas heater in hallway closet is unplugged and disconnected from gas; switch in the closet lacks cover.
07/23/2014 INSP - FOLLOW UP CODE ENFORCE Approved Site inspection; evaluation of electrical service by two electricians has occurred, one still on location; owner declined to proceed with repairing the hazardous electrical violations. All units were issued a notice to vacate for lack of safe electrical service; TEP was contacted for disconnect. Notice to vacate, indemification, and citation issued to owner.