Case: T14DV03004

Parcel: 12008594C


Addresses:

4876 S 6TH AV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
05/15/2014 INSP - INITIAL CODE ENFORCMENT Approved THERE IS AN 8 X 8 X 40 FOOT METAL CARPORT STRUCTURE THAT HAS BEEN MODIFIED INTO A DINING AREA FOR THE PEDDLER BUSINESS. THE CARPORT STRUCTURE HAS BEEN ENCLOSED BY USING T111 WOOD SHEATHING. THE WEST END OF THE STRUCTURE HAS LOCKED DOORS. THE EAST END IS OPENED TO THE PUBLIC AND CURRENTLY BEING USED AS A DINE IN AREA. THE CARPORT STRUCTURE IS ENERGIZED WITH LIGHTS AND RECEPTACLES. THERE IS MC CABLE AND EXTENSION CORD COMING FROM THE MAIN BUILDING PROVIDING POWER TO THE CARPORT STRUCTURE. THE 1998 AERIALS PHOTOS DO NOT SHOW THE STRUCTURE ON THE PROPERTY. THERE HAS BEEN NO BUILDING PERMIT ISSUED FOR THE STRUCTURE.

THE MAIN BUILDING IS A COMMISSARY BUSINESS. THERE IS AN ELECTRIC WATER HEATER AT REAR OF THE BUILDING WITH NO PROTECTIVE ENCLOSURE FOR THE UNIT THAT IS NOT RATED FOR OUT DOOR LOCATIONS. THE FLEX CONDUIT TO THE UNIT IS NOT CODE COMPLIANT. THE WATER HEATER LACKS A DISCHARGE PIPE. THE COVER PLATE TO THE WATER HEATER HAS RUST DUE TO THE OUTDOOR LOCATION WITH NO PROTECTION.

THE LISTED SERVICE EQUIPMENT BELOW WAS INSTALLED WITHOUT A PERMIT ITEMS TO INCLUDE BUT NOT LIMITED TO THE FOLLOWING.
A 100 AMP SQUARE D TYPE PANEL AND THE FLEX CONDUIT IS NOT CODE COMPLIANT. THE SOUTH SWITCH HAS EXPOSED FEEDERS GOING INTO THE BUILDING ALSO NOT CODE COMPLIANT. THE SERVICE MAIN SWITCH HAS MULTIPLE FEEDERS ON EACH LUG. THE GUTTER BOX HAS UNUSED OPENING WITH RUST.

THE NORTH SIDE OF THE BUILDING HAS AN EQUIPMENT DISCONNECT WITH NEUTRALS AND GROUNDS NOT SEPARATED. THE EQUIPMENT DISCONNECT IS NOT RATED FOR THE CURRENT USE AS A JUNCTION BOX.

THE EXTERIOR OF THE BUILDING HAS JUNCTION BOXES WITH MISSING COVER PLATES EXPOSED WIRING.

THERE IS A DUST TO DAWN LIGHT FIXTURE IS MOUNTED ON A WOOD POST AT THE NORTH END OF THE BUILDING. THE MOUNTING METHOD IS NOT AN APPROVED METHOD. THE POINT OF ATTACHMENT IT NOT CODE COMPLIANT. THE LIGHTING SYSTEM IS NOT IN COMPLIANCE WITH THE OUT DOOR LIGHTING CODE. THIS SYSTEM WAS INSTALLED WITHOUT A PERMIT.