Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-COMMERCL
Address:

Entered Date:

05/12/2014

Applicant:

NACHES SOUTHSIDE LLC RANDY P TAVEL

Description:

BUILDING AND ELECTRICAL VIOLATIONS

Case Violations

Case Number: T14DV03004
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Violations: 3
Violation Date Code Statue
05/15/2014 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
05/15/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
05/15/2014 T.C. Ch. 16, Sec. 16-14. Dilapidated structures; vacant and unsecured structures; buildings and structures constituting a nuisance. (a) Dilapidated structures. Buildings or structures that are so deteriorated, damaged, dilapidated, or in need of repair so as to present a threat to the health, safety and welfare of the community constitute a nuisance and shall be abated by repair, rehabilitation or demolition as provided in Article VI of this chapter.

Outstanding Inspections

Case Number: T14DV03004
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
12/01/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item closed
12/01/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item closed
12/01/2014 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Item closed
12/01/2014 NPO - WORK WITHOUT PERMIT VALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV03004
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/15/2014 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THERE IS AN 8 X 8 X 40 FOOT METAL CARPORT STRUCTURE THAT HAS BEEN MODIFIED INTO A DINING AREA FOR THE PEDDLER BUSINESS. THE CARPORT STRUCTURE HAS BEEN ENCLOSED BY USING T111 WOOD SHEATHING. THE WEST END OF THE STRUCTURE HAS LOCKED DOORS. THE EAST END IS OPENED TO THE PUBLIC AND CURRENTLY BEING USED AS A DINE IN AREA. THE CARPORT STRUCTURE IS ENERGIZED WITH LIGHTS AND RECEPTACLES. THERE IS MC CABLE AND EXTENSION CORD COMING FROM THE MAIN BUILDING PROVIDING POWER TO THE CARPORT STRUCTURE. THE 1998 AERIALS PHOTOS DO NOT SHOW THE STRUCTURE ON THE PROPERTY. THERE HAS BEEN NO BUILDING PERMIT ISSUED FOR THE STRUCTURE. THE MAIN BUILDING IS A COMMISSARY BUSINESS. THERE IS AN ELECTRIC WATER HEATER AT REAR OF THE BUILDING WITH NO PROTECTIVE ENCLOSURE FOR THE UNIT THAT IS NOT RATED FOR OUT DOOR LOCATIONS. THE FLEX CONDUIT TO THE UNIT IS NOT CODE COMPLIANT. THE WATER HEATER LACKS A DISCHARGE PIPE. THE COVER PLATE TO THE WATER HEATER HAS RUST DUE TO THE OUTDOOR LOCATION WITH NO PROTECTION. THE LISTED SERVICE EQUIPMENT BELOW WAS INSTALLED WITHOUT A PERMIT ITEMS TO INCLUDE BUT NOT LIMITED TO THE FOLLOWING. A 100 AMP SQUARE D TYPE PANEL AND THE FLEX CONDUIT IS NOT CODE COMPLIANT. THE SOUTH SWITCH HAS EXPOSED FEEDERS GOING INTO THE BUILDING ALSO NOT CODE COMPLIANT. THE SERVICE MAIN SWITCH HAS MULTIPLE FEEDERS ON EACH LUG. THE GUTTER BOX HAS UNUSED OPENING WITH RUST. THE NORTH SIDE OF THE BUILDING HAS AN EQUIPMENT DISCONNECT WITH NEUTRALS AND GROUNDS NOT SEPARATED. THE EQUIPMENT DISCONNECT IS NOT RATED FOR THE CURRENT USE AS A JUNCTION BOX. THE EXTERIOR OF THE BUILDING HAS JUNCTION BOXES WITH MISSING COVER PLATES EXPOSED WIRING. THERE IS A DUST TO DAWN LIGHT FIXTURE IS MOUNTED ON A WOOD POST AT THE NORTH END OF THE BUILDING. THE MOUNTING METHOD IS NOT AN APPROVED METHOD. THE POINT OF ATTACHMENT IT NOT CODE COMPLIANT. THE LIGHTING SYSTEM IS NOT IN COMPLIANCE WITH THE OUT DOOR LIGHTING CODE. THIS SYSTEM WAS INSTALLED WITHOUT A PERMIT.
11/25/2014 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved THE BUILDING WAS REMOVED, PHOTO TAKEN. CLOSE CASE

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-COMMERCL
Case Number - T14DV03004
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
05/15/2014 CONTACTED BY PHONE
05/29/2014 CONTACTED IN PERSON
05/16/2014 CONTACTED BY MAILING
12/01/2014 CONTACTED BY EMAIL
05/16/2014 NOTICE OF VIOLATION ISSUED
12/01/2014 VIOLATION CLOSED

Documents

File Name Document Type  
4876 S 6TH AV.PDF DOCUMENTS VIEW
4876 S 6TH AVE.JPG DOCUMENTS VIEW
PHOTO.JPG DOCUMENTS VIEW
IMAGE.JPEG DOCUMENTS VIEW
P4180098.JPG DOCUMENTS VIEW
P4240117.JPG DOCUMENTS VIEW
PHOTO.JPG DOCUMENTS VIEW
P4180096.JPG DOCUMENTS VIEW
P4180097.JPG DOCUMENTS VIEW
P4180098.JPG DOCUMENTS VIEW
P4180099.JPG DOCUMENTS VIEW
P4180100.JPG DOCUMENTS VIEW
P4180101.JPG DOCUMENTS VIEW
P4180102.JPG DOCUMENTS VIEW
P4180103.JPG DOCUMENTS VIEW
P4180104.JPG DOCUMENTS VIEW
P4180105.JPG DOCUMENTS VIEW
P4180106.JPG DOCUMENTS VIEW
P4180107.JPG DOCUMENTS VIEW
P4180108.JPG DOCUMENTS VIEW
P4180109.JPG DOCUMENTS VIEW
P4180110.JPG DOCUMENTS VIEW
P4180111.JPG DOCUMENTS VIEW
P4240117.JPG DOCUMENTS VIEW
P4240118.JPG DOCUMENTS VIEW
P4240119.JPG DOCUMENTS VIEW
P4300120.JPG DOCUMENTS VIEW
P4300121.JPG DOCUMENTS VIEW
P6300007.JPG DOCUMENTS VIEW
P6300008.JPG DOCUMENTS VIEW