Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/07/2014 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE, MET WITH TFD INVESTIGATORS WHO MENTIONED THERE WAS FILM OF THE FIRE AND THAT IT APPEARED THE FIRE STARTED AT THE BACK OF A FRY MACHINE BUT ACTUALLY ON THE MACHINE ITSELF. THE FIRE WAS UNDER THE HOOD AND ANCILLERY SYSTEM DID NOT GO OFF, FIRE WAS PUT OUT QUICKLY BUT THERE WAS MINOR CEILING DAMAGE. TFD CONTACTED THE HEALTH DEPT. CODE ENFORCEMENT. I ASKED THEY CONTACT S/W GAS WHICH THEY DID. I WAITED FOR S/W GAS, THEY CONDUCTED A LINE TEST THAT CHECKED OUT OK AND THEN TESTED APPLIANCES AND FOUND TWO VERY SMALL LEAKS AND A PLUGG THAT WOULD BE REQUIRED AND WAS MISSING BUT FITTING WAS CONNECTED TO A SHUT OFF VALVE, PROBABLY FOR A PREVIOUS APPLIANCE. THE ANCILLERY SYSTEM ALSO DID NOT GO OFF AS FIRE WAS CONTAINED WITHIN THE HOOD AREA. GAS WAS SHUT OFF AND LEFT OFF. OWNERS CLEANED THE INTERIOR OF THE STORE, DID A VERY NICE JOB WHILE WAITING FOR THE HEALTH DEPT. , ALL FOOD WAS THROUWN OUT, ALL MACHINES COUNTERS, POTS,PANS AND FLOORS WERE CLEANED. I EXPLAINED THAT THE ANCILLERY SYSTEM WOULD NEED TO BE CHECKED BY AMERICAN FIRE PROTECTION, THE GAS LINE WOULD REQUIRE THE REPAIRS AND A PRESSURE TEST FOR A RECONNECT (PERMIT REQUIRED) FOR THE STORE TO REOPEN. AMERICAN FIRE, COMPANY PLUMBER AND STORE MAINTANENCE WERE ALL CALLED FOR REPAIRS TO BE MADE WHILE ON SITE. LATER FOUND THAT A PERMIT HAD BEEN SECURED FOR THE RECONNECT. ** MARTIN LOPEZ WAS CALLED OUT FOR A F/U INSPECTION, FOUND THAT ALL REPAIRS HAD BEEN MADE TO THE CEILING AND TO THE GAS LINE BUT WAS INFORMED BY OWNER THAT THE PRESSURE TEST VALVE HAD BEEN REMOVED PRIOR TO THE RECONNECT INSPECTION AND THEREFORE FAILED INSPECTION. |