Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

05/02/2014

Applicant:

ATTN: MAS REAL ESTATE SVCS INC BROADWAY/CAMINO SECO LLC

Description:

EMERGENCY CALL CE01 AREA

Outstanding Inspections

Case Number: T14DV02773
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
05/12/2014 NPO(PL)-PLUMBING SYSTEM & FX BENCOMO Item closed
05/12/2014 NPO(PL)-GAS SUPPLY/CONNECT BENCOMO Item closed
05/12/2014 NPO - INT. BUILDING MAINTENANC BENCOMO Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV02773
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/07/2014 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved REVISITED SITE, OWNERS PROVIDED PAPERWORK FROM THE HEALTH DEPT., WHICH PASSED AND INTERIOR WAS COMPLETELY CLEANED AND FOOD THROWN OUT AT THE TIME OF THE FIRE. INSPECTOR WAS ON SITE AT THE TIME. OWNERS PROVIDE APPROVED INSPECTION PAPERWORK FOR THE PLUMBING CORRECTIONS, PRESSURE TEST, AND RECONNECT APPROVAL. AND I WAS FAXED PAPERWORK AND SPOKE TO PAUL FROM AMERICAN FIRE PROTECTION WHO APPROVED ANCILLERY SYSTEM. CEILING REPAIRS WERE MADE TO THE DROPPED CEILING. COMPLIANCE / CLOSE CASE.
05/07/2014 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATORS WHO MENTIONED THERE WAS FILM OF THE FIRE AND THAT IT APPEARED THE FIRE STARTED AT THE BACK OF A FRY MACHINE BUT ACTUALLY ON THE MACHINE ITSELF. THE FIRE WAS UNDER THE HOOD AND ANCILLERY SYSTEM DID NOT GO OFF, FIRE WAS PUT OUT QUICKLY BUT THERE WAS MINOR CEILING DAMAGE. TFD CONTACTED THE HEALTH DEPT. CODE ENFORCEMENT. I ASKED THEY CONTACT S/W GAS WHICH THEY DID. I WAITED FOR S/W GAS, THEY CONDUCTED A LINE TEST THAT CHECKED OUT OK AND THEN TESTED APPLIANCES AND FOUND TWO VERY SMALL LEAKS AND A PLUGG THAT WOULD BE REQUIRED AND WAS MISSING BUT FITTING WAS CONNECTED TO A SHUT OFF VALVE, PROBABLY FOR A PREVIOUS APPLIANCE. THE ANCILLERY SYSTEM ALSO DID NOT GO OFF AS FIRE WAS CONTAINED WITHIN THE HOOD AREA. GAS WAS SHUT OFF AND LEFT OFF. OWNERS CLEANED THE INTERIOR OF THE STORE, DID A VERY NICE JOB WHILE WAITING FOR THE HEALTH DEPT. , ALL FOOD WAS THROUWN OUT, ALL MACHINES COUNTERS, POTS,PANS AND FLOORS WERE CLEANED. I EXPLAINED THAT THE ANCILLERY SYSTEM WOULD NEED TO BE CHECKED BY AMERICAN FIRE PROTECTION, THE GAS LINE WOULD REQUIRE THE REPAIRS AND A PRESSURE TEST FOR A RECONNECT (PERMIT REQUIRED) FOR THE STORE TO REOPEN. AMERICAN FIRE, COMPANY PLUMBER AND STORE MAINTANENCE WERE ALL CALLED FOR REPAIRS TO BE MADE WHILE ON SITE. LATER FOUND THAT A PERMIT HAD BEEN SECURED FOR THE RECONNECT. ** MARTIN LOPEZ WAS CALLED OUT FOR A F/U INSPECTION, FOUND THAT ALL REPAIRS HAD BEEN MADE TO THE CEILING AND TO THE GAS LINE BUT WAS INFORMED BY OWNER THAT THE PRESSURE TEST VALVE HAD BEEN REMOVED PRIOR TO THE RECONNECT INSPECTION AND THEREFORE FAILED INSPECTION.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T14DV02773
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
05/08/2014 VIOLATION CLOSED