Permit: T14CM07545

Parcel: 13321074B


Addresses:

6327 E BROADWAY BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T14CM07545

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
03/25/2015 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
03/25/2015 REINFORCED MASONRY PRE-GROUT Approved CMU WALLS COMPLETE - TOPPED-OUT
03/24/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/24/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 24' 8" GL: F/3.5-8; 8/F-D; 8/C-A - OK TO GROUT PROGRESS AREAS
03/23/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/23/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL @ 24' 8" - GL: F/2-8 - OK TO GROUT PROGRESS AREA
03/18/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/18/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 12' - 16' GL: 8/A-F; F/3-8: CMU WALL @ 24'8" GL: 2/A-B - OK TO GROUT
03/16/2015 REINFORCED MASONRY PRE-GROUT Partial Approval cmu wall at 8'-12',gl: 8/a-f 12"-16", gl:f/3.5-8; 18'-20f, gl2/a-e ok to grout progress areas
03/11/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/11/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL @ 18' 8"; GL: 2/B.5-E; 1/E-F; 2/E.5-F; 16'-20'; GL: 1/E-F; F/1-3.5 - OK TO GROUT PROGRESS AREA
03/10/2015 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
03/06/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/06/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 8'-12' GL: 1/E-F; E/1-2; 2/E-D; CMU WALL @ 12;-16'; GL: 2/D-B.5 - OK TO GROUT
03/04/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/04/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 4'-8' GL: 8/A-B; 0'-4' GL: 8/B.25-C; 0'-4' GL: 8/C-F; F/3-8; 4'-8' GL: F/1-3; 2/F-E.75; 1/E-F; E/1-2; GL: 2/C-0.5- OK TO GROUT PROGRESS AREAS
02/19/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 24' 8: G L: A/2-8; GL: 8/A-B - OK TO GROUT
02/18/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/18/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL @ 20'-20' 4" - GL: A/2-7 - OK TO GROUT
02/17/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/17/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 16'-20' AFFE - GL: A/2-8; 2/A-B - OK TO GROUT PROGRESS AREAS
02/13/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/13/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 12'-16'; GL: A/2-7, 2/A-B; CMU WALLS @ 8'-12' @ GL: A/6.5-8, 8/A-B - OK TO GROUT PROGRESS AREAS
02/12/2015 REINFORCED MASONRY PRE-GROUT Partial Approval cmu wall at 4'-8' affe: gl :a/7-8; cmu wall at 8'-12'
gl:a/2-7; 2/a-b ok to grout progress area
02/11/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/11/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL @ GL: A/1-6 @ 8' - 12' - OK TO GROUT PROGRESS AREA
02/06/2015 REINFORCED MASONRY PRE-GROUT Partial Approval PER JBURGE OPEN
02/05/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/05/2015 REINFORCED MASONRY PRE-GROUT Partial Approval STEM WALL GROUT; GL: 8/A-F; A/2-8; 2/A-E - OK TO GROUT PROGRESS AREA
02/02/2015 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*