Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T14CM06599
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2017 | BUILDING PRE-SLAB | Approved | ||
07/05/2017 | BUILDING PRE-SLAB | Partial Approval | CRANE POUR-BACK SLAB 9'6" X 9'8" X 22". POUR BACK SLAB TO 6" DOWN TO JOIN EXIXTING SLAB. REMAINING 6" SLAB TO BE AT 3500 PSI AND MICRO FIBER ADDED. CHANGE APPROVED BY ARCHITECT AND ENGINEER. | |
01/30/2017 | BUILDING PRE-SLAB | Partial Approval | SLAB AREA IN QUESTION WAS INSPECTED ON 27 JANUARY 2017. | |
10/17/2016 | BUILDING PRE-SLAB | Partial Approval | LEVEL #8: METAL DECKING AND REBAR; REBAR AROUND SHAFTS IS TOO HIGH; BARS IN QUESTION NEED TO BE LOWERED FOR CLEARANCE TO TOP OF SLAB. OK TO POUR WHEN CORRECTIONS HAVE BEEN COMPLETED. | |
09/02/2016 | BUILDING PRE-SLAB | Partial Approval | LEVEL #7 - STEEL DECKING; OK TO POUR PROGRESS AREA. |