Permit: T14CM05234

Parcel: 108203010


Addresses:

4124 N FORTUNE LP

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/08/2015 PLUMBING - INTERMEDIATE Approved
03/02/2015 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
03/02/2015 PLUMBING - INTERMEDIATE Partial Approval OK TO COVER. PROVICE DOCUMENTATION FOR ALL CHANGES. #8 MIN BOND TO GAS REQUIRED OF 3908.12. INSTALL SAFETY PLATE M1308.2. SEAL PIPE IN TUB BOXES.