Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T14CM04154
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/25/2015 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
03/25/2015 | REINFORCED MASONRY PRE-GROUT | Approved | ALL CMU WALLS TOPPED-OUT | |
02/20/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
02/20/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU COLUMNS @ GL: 10/D, A/N, 1/B, 1/G @ 4'-8'; CMU WALL @ 4'-8', GL: 4/C-H; CMU WALL @ 8'-12'; GL: H/4-5; WALL @ 16'-24' (RAKED) GL: 5/J-N - TOPPED-OUT; CMU WALLS @ 24' (TOP-OUT) GL: K/6-9; 9/K-L, L/8-9 - OK TO GROUT PROGRESS AREAS | |
02/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
02/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS @ GL: 4/A-G; 0'-4' AFFE; GL: H/4-5 @ 4'-8' AFFE; GL: 5/J-N 16'-20' AFFE; COLUMNS @ 0'-4'; GL: 9/N; 10/D; 1/A; 1/F - OK TO GROUT PROGRESS AREAS | |
02/09/2015 | REINFORCED MASONRY PRE-GROUT | Correction Required | NEEDS TO SCHEDULE INSPECTIONS | |
02/09/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
02/05/2015 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
01/28/2015 | REINFORCED MASONRY PRE-GROUT | Cancelled | APPROVED IN ERROR | |
01/28/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | NEED INSPECTION | |
01/27/2015 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
01/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALL @ 16'-20' GL: K/7-9; 4'-8'; GL: 9/K-L; L/8-9; 16'-20'; GL: 6/J-K; J/6-7. CMU WALLS @ 0'-4'; GL: 5/J-N; N/5-7; 6/M-N - OK TO GROUT PROGRESS AREAS. **NOTE: TRAINING ROOM NORTH, SOUTH, & WEST WALLS ARE TAPPED-OUT - INSPECTIONS PERFORMED FOR 0'-4' ONLY. SUPERINTENDENT CALLED FOR INSPECTIONS; GRANTED CONFIRMATION NUMBER, BUT A WORK REQUEST WAS NOT PRINTED. ALL SUBJECT WALLS HAVE BEEN SPECIAL INSPECTED. |
|
01/26/2015 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
01/12/2015 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
01/06/2015 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
12/31/2014 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 8'-12' AT GL: J/5-6.75; B/4-5; 4/A-B; A/2-4; 2/A-E; 2/F-I; I/2-3.5; 4'-8' GL: I/3.5-4; OK TO GROUT PROGRESS AREAS | |
12/30/2014 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
12/19/2014 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 4'-8' (2ND LIFT) GL: J/5-6; (72" @ B/4-5); 4/C-B; A/2-4; 2/A-I; I/2-2.5 - OK TO GROUT | |
12/18/2014 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
12/17/2014 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - AP canceled | |
12/12/2014 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1ST LIFT AT 48" AFFE: GL: K/6-8.5, 6/J-K, J/5-6, B/4-5, 4/C-B, A/2-4, 2/A-I, I/2-4 - OK TO GROUT PROGRESS AREAS | |
12/08/2014 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* |