Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T13CM07156

Parcel: 117030880


Addresses:

826 N 7TH AV


Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Permit Number - T13CM07156

Inspection Description - PLUMBING - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
12/02/2013 PLUMBING - FINAL Not ready for Inspection 1. ABS shall change direction no more than 45 degrees. ABS requires twelve inches of cover. (Nochange required) ABS not approved outside above grade. Remember: Cleanouts to open in the direction of flow. OK to cover all non-affected areas.
12/02/2013 PLUMBING - FINAL Approved