Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T13CM04494
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/23/2014 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 09/12/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 09/12/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1ST LIFT TRASH ENCLOSED | |
| 09/03/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 09/03/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | WEST RETAINING WALL FTING | |
| 08/27/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 08/27/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | POLE BASE S/E CORNER | |
| 08/25/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* NORTH ENTRY STAIRS | |
| 08/19/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 08/13/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 06/18/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 06/18/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | EAST SEAT WALLS | |
| 03/27/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 03/27/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | SLAB AT WATER TANK OK TO POUR | |
| 03/25/2014 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 03/17/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 03/17/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | EXTERIOR STAIRS AND LANDING NW SIDE | |
| 03/03/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 03/03/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | EXTERIOR STAIRS MAIN BLDG WESTSIDE | |
| 02/21/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1. OK to pour column pads on South side of bldg. Column pads per details #124, and #126 on sheet S4.0 Stem walls at poured column pads OK. Wrap rain water leader where they will be encased in concrete- to be tested at a later date. | |
| 01/30/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/30/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | EAST COLUMNS OK | |
| 01/29/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/29/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | BREEZEWAY COLUMNS 2ND LIFT OK | |
| 01/28/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/28/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | BREEZEWAY COLUMNS 1ST LIFT | |
| 01/27/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/23/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/23/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | EXTERIOR MATS OK TO POUR | |
| 01/15/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/15/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | INTERIOR STEM - 100% PASS. BREEZEWAY FOOTING OK | |
| 01/10/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/10/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | INTERIOR MATS EAST BLDG. CENTER MATS WEST BLDG. | |
| 01/08/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/08/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | NE STEM, WEST INTERIOR MATTS OK | |
| 01/06/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/06/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | FOOTING NW CORNER MAIN BLDG | |
| 01/02/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 01/02/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | EAST STEM WALL | |
| 12/31/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 12/30/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | STEM WALL AT WEST WALL | |
| 12/26/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 12/26/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | STEM/FOOTING SOUTH WALL | |
| 12/24/2013 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 12/24/2013 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | GL BLDG ALONG WEST SIDE LINE 10, BOXES ON SOUTH LINE 13 | |
| 12/23/2013 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 12/23/2013 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | ||
| 12/13/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 12/12/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | GL: N-T/1, T/1-9, 9/N-T, & N/1-9 AND CHAPLEY TOWER FOUNDATION OK | |
| 12/09/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | PARTIAL APPROVAL FROM A/10 TO K/8. | |
| 12/06/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 12/06/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | CENTER LINE INTERIOR MATTS - OK TO POUR | |
| 12/04/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 12/04/2013 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | LIGHT POLE - CONDUIT OK NORTHSIDE PARTIAL FOOTING EAST & NORTHSIDES OF MAIN BUILDING |