Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T13CM02031
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/13/2013 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
08/12/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
08/12/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | - TESTING WITH RICHARD FROM STANTEC L-M ONLY - TESTING HCS CONNECTION ALONG NORTH RUN UNDER SUPERVISION OF JOHN WARD |
|
08/09/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
08/09/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | MIDDLE MANHOLE NORTHSIDE HELD 6 LBS 10 MIN | |
08/07/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | INSTALLING HCS CONNECTIONS | |
08/05/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
08/05/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | BACKFILLING CONN TO MH 5 OK |
|
08/01/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
08/01/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | PS 58, PS 22, 23 OR SUBJECT TO TESTING | |
07/30/2013 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
07/29/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/25/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/25/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | HCS CONNECTIONS BETWEEN 6 & 9, 7 & 9 | |
07/24/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/24/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | MAIN PIPING BETWEEN 6 & 7 OK; SUBJECT TO TESTING. INSTALLING HCS LATERALS. BRANCH LINES NEED TO BE INSTALLED AT ANGLES OF 45 DEGREES, 16 DEGREES, OR HORIZONTAL W/ SLOPE FOR CONNECTING TO. | |
07/23/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/22/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/22/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | - PIPING & CONN EXISTING MH #9 - PIPING W/ WYE FITTINGS BETWEEN MH #7 & MH #6 |
|
07/19/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/18/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/17/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/16/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/09/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/09/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | AIR TESTING PS 20-21, 38-41 PER PC STANDARD TEST METHOD ASTM 1417 | |
07/08/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/08/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | PS 28 & 29 OK TO COVER SUBJECT TO AIR TESTING USE CAUTION TO KEEP ALL ROCKS OFF PIPE |
|
07/03/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/03/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | - SDR 35 6" W 4" BRANCHES - PS41 & 41B OK TO SHADE & COVER - PS 38, 39, & 39B OK TO SHADE & COVER |
|
07/02/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
07/02/2013 | PLUMBING - SEWER HCS CONNECT | Partial Approval | - PS 21 OK TO SHADE & BACKFILL - PS 20 OK TO SHADE & BACKFILL |