Permit: T13CM02031

Parcel: 99999999A


Addresses:

10901 E DREXEL RD


Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T13CM02031

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
08/13/2013 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
08/12/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
08/12/2013 PLUMBING - SEWER HCS CONNECT Partial Approval - TESTING WITH RICHARD FROM STANTEC L-M ONLY
- TESTING HCS CONNECTION ALONG NORTH RUN UNDER SUPERVISION OF JOHN WARD
08/09/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
08/09/2013 PLUMBING - SEWER HCS CONNECT Partial Approval MIDDLE MANHOLE NORTHSIDE HELD 6 LBS 10 MIN
08/07/2013 PLUMBING - SEWER HCS CONNECT Partial Approval INSTALLING HCS CONNECTIONS
08/05/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
08/05/2013 PLUMBING - SEWER HCS CONNECT Partial Approval BACKFILLING
CONN TO MH 5 OK
08/01/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
08/01/2013 PLUMBING - SEWER HCS CONNECT Partial Approval PS 58, PS 22, 23 OR SUBJECT TO TESTING
07/30/2013 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
07/29/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/25/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/25/2013 PLUMBING - SEWER HCS CONNECT Partial Approval HCS CONNECTIONS BETWEEN 6 & 9, 7 & 9
07/24/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/24/2013 PLUMBING - SEWER HCS CONNECT Partial Approval MAIN PIPING BETWEEN 6 & 7 OK; SUBJECT TO TESTING. INSTALLING HCS LATERALS. BRANCH LINES NEED TO BE INSTALLED AT ANGLES OF 45 DEGREES, 16 DEGREES, OR HORIZONTAL W/ SLOPE FOR CONNECTING TO.
07/23/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/22/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/22/2013 PLUMBING - SEWER HCS CONNECT Partial Approval - PIPING & CONN EXISTING MH #9
- PIPING W/ WYE FITTINGS BETWEEN MH #7 & MH #6
07/19/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/18/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/17/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/16/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/09/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/09/2013 PLUMBING - SEWER HCS CONNECT Partial Approval AIR TESTING PS 20-21, 38-41 PER PC STANDARD TEST METHOD ASTM 1417
07/08/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/08/2013 PLUMBING - SEWER HCS CONNECT Partial Approval PS 28 & 29 OK TO COVER
SUBJECT TO AIR TESTING
USE CAUTION TO KEEP ALL ROCKS OFF PIPE
07/03/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/03/2013 PLUMBING - SEWER HCS CONNECT Partial Approval - SDR 35 6" W 4" BRANCHES
- PS41 & 41B OK TO SHADE & COVER
- PS 38, 39, & 39B OK TO SHADE & COVER
07/02/2013 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
07/02/2013 PLUMBING - SEWER HCS CONNECT Partial Approval - PS 21 OK TO SHADE & BACKFILL
- PS 20 OK TO SHADE & BACKFILL