Case: T12DV07803

Parcel: 11943001A


Addresses:

1655 W AJO WY #166


Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T12DV07803

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2013 INSP - FOLLOW UP CODE ENFORCE Approved ALL VIOLATIONS ABATED CLOSE CASE.
02/01/2013 INSP - FOLLOW UP CODE ENFORCE Approved ON SITE INSPECTION RESULTS; THE MC CABLE IS ATTACHED FROM J BOX TO UNKNOWN EXTERIOR OF THE MOBILE HOME, THIS IS AN ILLEGAL EXTENSION OF A CIRCUIT. THERE ARE TWO WOOD FRAMED WALLS UNDER THE REAR PART OF THE AWNING, ALSO A VIOLATION. PHOTOS WERE TAKEN. INFRACTION HEARING SET FOR TODAY AT 1000AM, SEE COURT NOTES IN CONDITIONS
11/20/2012 INSP - FOLLOW UP CODE ENFORCE Approved THE SIDES TO THE ADDITION WERE REMOVED.

THE CIRCUIT THAT HAS BEEN EXTENDED STILL EXISTS AND IS IN USE.
THE WIRING METHODS ARE UNAPPROVED. THE EXTERIOR JUNCTION BOX FASTENED TO THE MOBILE HOME DOES NOT HAVE THE REQUIRED PROTECTED COVER, THIS IS THE LOCATION WERE THE CIRCUIT CONTINUES BY MEANS OF METAL CLAD CABLE WHICH IS SECURED THE TO MOBILE HOME AND RUNS TO ANOTHER JUNCTION BOX THAT IS NOT PROPERLY FASTED THE MOBILE HOME, AT THIS LOCATION THERE IS NONMETALLIC-SHEATHED CABLE THAT IS BEING FEED FROM THE SECOND JUNCTION BOX RUNNING TO AN UNKNOWN SOURCE.