02/27/2012 INSP - INITIAL CODE ENFORCMENT Approved The carport in question is constructed of steel post and beam with corrugated steel roofing. Posts 4"x 4" and anchored into the concrete slab with 4 bolts per post and there are 6 posts. The beams are 8" channel beams, typically used in commercial carport applications, connected with bolts. Presumably the corrugated steel roofing is attached with self-sealing Tek screws as is typical in metal carport applications.
A Review of aerial photos show that structure was erected somewhere between 1998 and 2002. The carport is not dangerous or built in a sub-standard manner. The closest adjacent structure is to the west and approximately 30' away. The carport structure is solid and sound as built and is an excellent start of repair.
The other structure in question is a metal storage shed in the N/W corner of the rear perimeter yard. The shed appeared on the aerial photos during the same time period as the carport. I could not identify and electrical to the shed. The shed is setback from the east property line approximately 6' at the north end and 5' at the south end of the shed itself and approximately 15' from the neighboring residence to the east.
Given the circumstances; age of the structures, setbacks, construction materials, construction methods and present condition of the structures, it is my recommendation that a Code Compliance permit and inspection(s) would be appropriate.