Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL
Address:

Entered Date:

02/24/2012

Applicant:

MARY E. WILKES

Description:

PDSD referral: A solar company went out to this location and placed solar panels a couple of months ago according to the owner. Solar company may not have pulled permits prior to installing the panels. They apparently came in after the fact to get a permit and were denied by zoning due to unpermitted structures on the property. I think the company that placed the panels will not be coming back to final the permit therefore the panels have not been inspected and probably will not get inspected. Also, look at the possible illegal carport and rear structures.

Case Violations

Case Number: T12DV01475
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 1
Violation Date Code Statue
02/27/2012 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T12DV01475
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
04/05/2012 LUC - VIOL OF SITE PLAN - COND DCOX Item closed
04/05/2012 NPO - WORK WITHOUT PERMIT DCOX Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV01475
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 1
End Date Description Inspector Results Comments
02/27/2012 INSP - INITIAL CODE ENFORCMENT DCOX Approved The carport in question is constructed of steel post and beam with corrugated steel roofing. Posts 4"x 4" and anchored into the concrete slab with 4 bolts per post and there are 6 posts. The beams are 8" channel beams, typically used in commercial carport applications, connected with bolts. Presumably the corrugated steel roofing is attached with self-sealing Tek screws as is typical in metal carport applications. A Review of aerial photos show that structure was erected somewhere between 1998 and 2002. The carport is not dangerous or built in a sub-standard manner. The closest adjacent structure is to the west and approximately 30' away. The carport structure is solid and sound as built and is an excellent start of repair. The other structure in question is a metal storage shed in the N/W corner of the rear perimeter yard. The shed appeared on the aerial photos during the same time period as the carport. I could not identify and electrical to the shed. The shed is setback from the east property line approximately 6' at the north end and 5' at the south end of the shed itself and approximately 15' from the neighboring residence to the east. Given the circumstances; age of the structures, setbacks, construction materials, construction methods and present condition of the structures, it is my recommendation that a Code Compliance permit and inspection(s) would be appropriate.

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T12DV01475
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
02/28/2012 CONTACTED BY MAILING
02/27/2012 NOTICE OF VIOLATION ISSUED
04/05/2012 VIOLATION CLOSED

Documents

File Name Document Type  
T12DV01475.PDF DOCUMENTS VIEW