Permit: T12CM07703

Parcel: 14035002B


Addresses:

3901 E BENSON HY

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
02/19/2013 PLUMBING - PROGRESS Approved 1. low voltage to be removed to jbox
2. pipe and flex to be strapped
3. cooler termination to be inspection ground missing
4. llight fixtures to be installed completely
5. ceiling boxes missing k.o seals
6. strap mc at backroom
7. gfi missing in retail
8. roof to be inspected
9. compressor fuss paperwork missing labes
02/14/2013 PLUMBING - PROGRESS Not ready for Inspection complee work and noted corrections protect line set insulation protect exposed plastic will not alien horizontial abs abv roof. provide a plan revision for new a/c units include required fresh air makeup seal all threaded openings in dwv system suppport exp tank and piping.Pipe relief valve to exterior install hose thread vacuum breaker strerliation as specified with documentation
02/01/2013 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
01/28/2013 PLUMBING - PROGRESS Partial Approval INTERCEPTOR OK CAST IRON OR GALVANIZED REQUIRED ON EXPOSED EXTERIOR