Permit: T12CM07440

Parcel: 134234110


Addresses:

6310 E BROADWAY BL

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
08/08/2013 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
08/08/2013 REINFORCED MASONRY PRE-GROUT Approved TRASH ENCLOSURE & COMPACTOR COMPLETE
08/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT COMPACTOR AREA & TRASH ENCLOSURE - 1ST LIFT AT 48" A.F.F.E. - OK TO GROUT PROGRESS AREAS
07/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 24' 8" GL: 5/A.5-E.5; A/4.5-1.5; CMU WALLS AT 28' 8" GL: A-B/1-1.5; A-A.5/4.5-5
OK TO GROUT PROGRESS AREAS
07/26/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/26/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WAlls AT 20'
GL S A-D
GL A 1-5
07/25/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
07/24/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/24/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 16': GL: 1/D.5-F; CMU WALLS AT 16'-20'; GL: F/1.5-5; 5/A-F; A/2.5-5 - OK TO GROUT PROGRESS AREAS
07/23/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
07/23/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CONTRACTOR CANCELED
07/22/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/22/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 12'-16'; GL: 1/C-F; F/1-5; 5/A-F; A/2.5-5 - OK TO GROUT
**NOTE: SOUTH WALL - IMBEDS PLACED PER PLANS - SPECIAL INSPECTION 07/20/13 @ 12:00 PM**
07/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 8'-12' GL: 1/E-F; F/1-1.5
OK TO GROUT PROGRESS AREA
07/18/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/18/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 8'-12'; GL: F/1-4.4; 1/A.5-F; 5/B-D
OK TO GROUT PROGRESS AREA
07/17/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/17/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS TOPPED OUT AT 7'4" GL: A/1.5-2.5; 1/A-B; 1/A.5-C; CMU WALLS AT 8'0"; GL: 1/C-F, F/1-5.0; 5/A-F; A/1.5-5
OK TO GROUT PROGRESS AREAS
07/15/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
07/15/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CONTRACTOR CANCELED
07/12/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/12/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 48" GL: F/1-4.6; 5/C.5-E.6
OK TO GROUT PROGRESS AREAS
07/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
07/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 68" (1ST LIFT) GL: 1/A-F; A/1-5; 5/A-C.5
OK TO GROUT PROGRESS AREAS
06/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CONTINUOUS STEM WALLS (BUILDING - DRIVE THRU - TRASH ENCLOSURE) OK TO GROUT