Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T12CM07440
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/08/2013 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
08/08/2013 | REINFORCED MASONRY PRE-GROUT | Approved | TRASH ENCLOSURE & COMPACTOR COMPLETE | |
08/07/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/07/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT COMPACTOR AREA & TRASH ENCLOSURE - 1ST LIFT AT 48" A.F.F.E. - OK TO GROUT PROGRESS AREAS | |
07/29/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/29/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 24' 8" GL: 5/A.5-E.5; A/4.5-1.5; CMU WALLS AT 28' 8" GL: A-B/1-1.5; A-A.5/4.5-5 OK TO GROUT PROGRESS AREAS |
|
07/26/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/26/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WAlls AT 20' GL S A-D GL A 1-5 |
|
07/25/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
07/24/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/24/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 16': GL: 1/D.5-F; CMU WALLS AT 16'-20'; GL: F/1.5-5; 5/A-F; A/2.5-5 - OK TO GROUT PROGRESS AREAS | |
07/23/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
07/23/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | CONTRACTOR CANCELED | |
07/22/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/22/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 12'-16'; GL: 1/C-F; F/1-5; 5/A-F; A/2.5-5 - OK TO GROUT **NOTE: SOUTH WALL - IMBEDS PLACED PER PLANS - SPECIAL INSPECTION 07/20/13 @ 12:00 PM** |
|
07/19/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/19/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 8'-12' GL: 1/E-F; F/1-1.5 OK TO GROUT PROGRESS AREA |
|
07/18/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/18/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 8'-12'; GL: F/1-4.4; 1/A.5-F; 5/B-D OK TO GROUT PROGRESS AREA |
|
07/17/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/17/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS TOPPED OUT AT 7'4" GL: A/1.5-2.5; 1/A-B; 1/A.5-C; CMU WALLS AT 8'0"; GL: 1/C-F, F/1-5.0; 5/A-F; A/1.5-5 OK TO GROUT PROGRESS AREAS |
|
07/15/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
07/15/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | CONTRACTOR CANCELED | |
07/12/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/12/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS @ 48" GL: F/1-4.6; 5/C.5-E.6 OK TO GROUT PROGRESS AREAS |
|
07/11/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/11/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS @ 68" (1ST LIFT) GL: 1/A-F; A/1-5; 5/A-C.5 OK TO GROUT PROGRESS AREAS |
|
06/19/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
06/19/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CONTINUOUS STEM WALLS (BUILDING - DRIVE THRU - TRASH ENCLOSURE) OK TO GROUT |