Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2013 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/13/2013 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/12/2013 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 09/12/2013 | PLUMBING - FINAL | Denied | LAV CARRIERS SPECIFIED. PROVIDE DOCUMENTATION TO DELETE FLOOR MOUNTED CARRIERS OR INSTALL. ALL CLEANOUT PLUGS SHALL BE LISTED TO RECEIVE SCREW. REPLACE DAMAGED PLUGS. CONNECT CONDENSATE INDIRECTLY TO TAIL PIECE. INSTALL EXP TANK AFTER CHECK VALVE. INSTALL VACUUM RELIEF VALVE ON WH SUPPLY. ABS MAY NOT BE SOLVENT CEMENTED TO PVC. USE PVC TRAP ADAPTOR, USE PVC PRIMER. STERILIZATION. DUCT SMOKE DETECTOR TESTS. |