Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/17/2012 | ELECTRIC - INTERMEDIATE | Approved | 1. SERVICE BRACING AND GROUNDING TO BE TO CODE 2. PLUMBING IN WALLS OK 3. WIRING IN WALLS OK |
|
| 05/15/2012 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/14/2012 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE NM CABLE 8" SINGLE GAUGE 12" OTHERS & 8" OF PANLE OPENING 2) TERMANATE CONDUCTURS 3/4 OF TURN UNDER SCREW 3) PROTECT CONDUCTORS FROM SCREWS 4) PROTECT CABLE AT STUDS 5) FILL UNUSED OPENING IN BOX 6) BOXES TO BE RATED FOR FANS 7) SMOKE DETECTER LOCATION 8) GROUND METAL BOXES 9) AFCI WIRING TO BE PER 210.12 |