Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/09/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/08/2011 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SINGLE WALL REQUIRES 6" CLEARANCE AND MAY NOT BE INSTALLED OUTSIDE OF ENCLOSURE 2) FLEX MAY NOT PENETRATE WALL OF ENCLOSURE NOTE: HOME OWNER USING UNLICENSED INSTALLER FOR INSPECTIONS-STILL NOT PER MINIMUM STANDARDS |
|
| 09/06/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PLUG TEE AT GAUGE LOCATION 2) INSTALL ENCLOSURES 3) INSULATE EXT. PIPING 4) SECURE ALL WATER PIPING 5) COPPER AND GALV. MAY NOT BE INTERMEMBERED 6) INSTALL VACUUM BREAKERS ON NEW HOSE BIBS |
|
| 08/31/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REMOVE B-VENT TRANSITION PIECE AND INSTALL A 2' SECTION OF TYPE B-VENT 2) ALL EXTERIOR WATER PIPING REQUIRES FREEZE PROTECTION |
|
| 08/30/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) WATER HEATER AT HOUSE MAY NOT BE LOCATED ON UTILITY EASEMENT 2) COMPLETE WATER HEATER INSTALL FOR MAIN HOUSE AND SUPPORT ALL PIPING |