Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T11PL01279
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2011 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TEST ON ENTIRE SYSTEM TO HOLD WITH NO LOSS OF PRESSURE FOR 15 MINUTES |
|
09/21/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
09/01/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) GAUGE IS NON OPERATIONAL (DIAL IS WARPED) TEST WITH GOOD GAUGE. 2) A YELLOW APPLIANCE CONNECTOR IS NOT THE SAME THING AS A MOBILE HOME FLEX CONNECTOR. INSTALL MOBILE HOME FLEX CONNECTOR. RETEST SYSTEM WITH GOOD GAUGE AND RECALL FOR INSPECTION |
|
08/30/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
08/04/2011 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) UNDERGROUND GAS PIPING INSTALLED OK PRESASURE TEST OK OK TO CO ER 2)MAKE CORRECTION AT MOBILE HOME AND TEST ENTIRE SYSTEM 3) DID NOT ENTER RESIDENCE |