Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/20/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/23/2011 | ELECTRIC - FINAL | Denied | 1. SERVICE APPEARS TO HAVE BEEN RELOCATED - BY THE APPEARANCE OF OVERHEAD FEEDER CONNECTION. 2. SERVICE UPGRADE/RELOCATE PERMIT NEEDED. 3. ANY QUESTIONS CALL RAY MAJUTA AT 909-4891 4. NO ACCESS TO DETACHED GARAGE 5. BLANK SPACERS NEEDED AT OPEN KNOCK OUTS AT SUB-PANEL DEAD FRONT 6. BUSHING NEEDED AT BACK OF SUB PANEL AROUND HOME RUNS LOAD CONNECTORS. 7. DOUBLE CONDUCTOR UNDER SINGLE BREAKER AT SUB-PANEL 8. GROUNDS & NEUTRALS NEED TO BE SEPARATED AT SUB-PANEL 9. TOO MANY NON-CODE COMPLIANCE ITEMS TO LIST. 10. CONTACT LICENSED ELECTRICAL CONTRACTOR TO BRING UP TO CODE. |