Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T11EL01658
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/29/2011 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
06/24/2011 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
06/22/2011 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
06/21/2011 | ELECTRIC - RECONNECT | Denied | UNIT #15209: 1) PANE IN CLOSET HAS A WHITE WIRE CONNECTED TO A 20 AMP BREAKER 2) GROUNDS AND NEUTRALS NOT TO BE CONNECTED TOGETHER AT PANEL UNIT #15208: 1) SAMW AS UNIT #15209, 30 AMP FUSE ON COOLER SHOULD BE 20 OR 15 AMP UNIT #12104: 1) NEUTRALS AND GROUNDS CANNOT BE CONNECTED TOGETHER AT PANEL UNIT #1209: 1) NEUTRALS AND GROUNDS CANNOT BE CONNECTD TOGETHER AT PANEL |