Case: T11DV05415

Parcel: 10603013A


Addresses:

110 E PRINCE RD #13


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T11DV05415

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
07/26/2011 INSP - INITIAL CODE ENFORCMENT Approved UNIT # 13
VISITED SITE: MET W/ OCCUPANT. (PIC'S)
FRONT ENTRY STEP TREADS LOOSE.
FRONT PORCH LIGHT HANGING BY WIRES. 1 WIRE DISCONNECTED, ELECT. ENERGIZED.
FRONT DOOR LACKS PROPER WEATHER PROPECTION, WEATHERSTRIPPING HANGING FROM DOOR.
KITCHEN LIGHT FIXTURE LACKS REQUIRED COVER.
COOK STOVE EXHAUST FAN DOES NOT OPERATE AS INTENDED.
LIVINGROOM COOLER LACKS REQUIRED PROTECTIVE COVER. OPENING TO INTERIOR FAN.
FLOOR SHOWS SEVERAL WEAK SPOTS THROUGH OUT UNIT.
HALLWAY WALL WHERE MEETS FLOOR DETERIORATED FROM WATER LEAK.
PATCHWORK/REPAIR NOT AN ACCEPTABLE METHOD, FOAM..
CONVENIENCE OUTLETS LOOSE, SOME DO NOT OPERATE AS INTENDED. THROUGHOUT.
BEDROOM 1) LACKS REQUIRED ACCEPTABLE MEANS OF EGRESS.
BUNK BEDS BLOCK ANY AND ALL EGRESS.
SOUTH WALL UNDER WINDOW DETERIORATED DUE TO WATER LEAK.
CONVENIENCE OUTLET ON SOUTH WALL UNDER WINDOW SHOWS DETERIORATION DUE TO WATER LEAKING IN OUTLET.
BEDROOM 2) WINDOW AND FRAME BROKEN.
LEAKS WHEN RAINS.
BATHROOM 2 HOLES IN DOOR.
BATHROOM SINK CONTINOUSLY LEAKS.
BATHROOM SINK VANITY INTERIOR BOTTOM DETERIORATED DUE TO WATER LEAK. WRONG APPLICATION OF REPAIR.
BATH VANITY DRAWERS BROKEN OR MISSING.
BATH TUB/SHOWER DOORS BROKEN, FRAME/SEAL OFF DOORS.
TUB/ SHOWER AREA WALLS LACKS REQUIRED PROTECTIVE COVERING. WATER DETERIORATION.
HALLWALL INTERIOR WALL DETERIORATED, HOLE COVER WITH CARDBOARD & TAPE.
WHERE WALL MEETS FLOOR DETERIORATED.
CONVENIENCE OUTLET DOES NOT OPERATE, RAN WIRE OUT OF OUTLET BOX.
ELECTRICAL SUB-PANEL RE-LOCATED INTO HOT WATER HEATER ROOM.
LACKS REQUIRED SPACING FOR ANY AND ALL REPAIR WORK.
HOT WATER HEATER REPLACED NOT A MOBILE HOME HOT WATER HEATER.
LACKS EMERGENCY COLD WATER SHUT OFF.
HOT WATER TANK ENCLOSER ROOM LACKS DOOR.
HOT WATER TANK ROOM FLOOR DETERIORATED FROM WATER LEAK, HOLES ALLOWS FOR ANIMALS TO ENTER LIVING SPACE.
ELECTRICAL LIFE LINE CORD TO SHORT.
ALUMINUM FROM SKIRTING SHARP EDGES ON LIFE LINE CORD.