Case: T11DV02341

Parcel: 113061060

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
08/05/2011 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE:
PROPERTY NOT IN COMPLIANCE @ THIS TIME.
WINDOW CRANKS NOT INSTALLED.
NEW EXHAUST VENTS INSTALLED. ISSUE:
LEFT OLD EXHAUST VENT TUBE THROUGH ROOF, INSTALLED RIGHT NEXT TO OPENING, WILL ONLY PULL AIR FROM OLD VENT TUBE, NOT BATHROOM.
SEE COND.
05/05/2011 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE; COMPLETED INSP.
KITCHEN RECP. SHOW OPEN GROUND UNDER TEST.
KITCHEN WINDOW DOES NOT OPERATE AS INTENDED, LACK WINDOW CRANK.
STOVE EXHAUST LACKS FAN AND COVER.
HOT WATER TANK REPLACED (NEW). LACKS ENCLOSER, WATER LINES REPLACED.
REAR PATIO PORCH ROOF DETERIORATED, HOLES IN WOOD FROM DETERIORATION.
2X4 RAFTERS FOR PATIO PORCH OVERSPANED, STARTING TO BOW IN MIDDLE.
WEST BEDROOM WINDOW DOES NOT CLOSE ALL THE WAY.
BEDROOM WINDOW CRACKED.
BATH LACKS EXHAUST FAN AND COVER.
ALL NEW ELECT. FOR ALL 3 UNITS. SERVICES PANELS AND CONDUIT.
GAS LINE REPLACED FOR INTERIOR WALL HEATER. WALL & FLOOR.
REAR PORCH LIGHT LACKS PROTECTIVE COVER.