Case: T11DV02047

Parcel: 120071280


Addresses:

4048 S 6TH AV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
03/30/2011 INSP - INITIAL CODE ENFORCMENT Approved 3-29-2011 TFD WAS CALLED OUT TO A HAZARDOUS ELECTRICAL CALL. THE TENNANT STATED HE SMELLED SOMETHING BURNING.

ON SITE INSPECTION, FOUND THE EAST PORTION OF THE INTERIOR OF THE HOME IS BEING POWERED BY EXTENSION CORDS COMING FROM THE REAR WEST END OF THE HOME. LIVING, KITCHEN AND BEDROOMS HAVE NEW OPEN JUNCTION BOXES WITH NEW ROMEX CABLES IN THE CEILING AREAS, SOME THE ROOMS HAVE DRYWALL CUT OUTS IN THE CEILING AND WALLS. THE KITCHEN'S CEILING AREA ABOVE THE CEILING JOIST THERE ARE ROMEX CABLES ATTACH BY WIRES NUTS. THE BEDROOM'S CEILING AREA HAS A JUNCTION BOX WITH QUESTIONABLE AMOUNT OF WIRES IN THE BOX, NO COVER PLATE. THESE AREA'S IN THE CEILING LOOK LIKE THE SPLICED CONNECTIONS AND JUNCTION BOXES WILL BE ENCLOSED BY DRYWALL.

THE MAIN DISCONNECT HAS NEW BREAKERS, WIRING AND CONDUIT. A 30 AMP BREAKER WITH NUMBER 12 WIRE WAS TRIPPING, THE CIRCUIT WAS UNABLE TO BE TRACE. THE WIRE WAS DISCONNECTED FROM THE BREAKER BY COT. THE MAIN DISCONNECT DOES NOT HAVE A GROUNDING ELECTRODE CONDUCTOR. THERE IS STRAND WIRE WHICH IS BEING USED AS A GROUND JUMPER WIRE FROM THE MAIN DISCONNECT WHICH ENTERS THE NEW SQUARE D PANEL BOARD THEN IS LOOPED TO THE OLD DISCONNECTS BUS BAR WHICH DOES HAVE A GROUNDING ELECTRODE CONDUCTOR TO A ROD.

THE NEW SQUARE D PANEL BOARD HAS THE MAIN TERMINALS WHICH ARE DOUBLE LUGGED. THE JUMPER WIRES RUN OVER TO THE OLD DISCONNECT WHICH NOW IS BEING USED AS A PANEL BOARD TO PROVIDE POWER TO THE DWELLING. THE SQUARE D PANEL BOARD HAS 8 NEW CIRCUIT BREAKERS WITH NEW NUMBER 12 ROMEX CABLES WHICH LEADS INTO THE HOME. ONE OF THE CIRCUIT 30 AMP BREAKER IS USING A NUMBER 10 WIRE TO A 15 AMP OUTDOOR RECEPTACLE. THE EXTERIOR OF THE BUILDING HAS AN OPEN JUNCTION BOX WHICH SHOWS CABLES ENTERING THE DWELLING.

THERE IS A SECOND GROUNDING ELECTRODE CONDUCTOR WHICH HAS BEEN CUT NEXT TO THE OLD DISCONNECT. ALL THE CIRCUITS IN THE PANEL BOARDS ARE NOT MARKED, IT IS UNKNOWN WHICH CABLES AND DEVICES ARE ENERGIZES IN THE HOME. ALL THE BREAKERS WERE ON THE ON POSITION BUT YET HALF OF THE HOME LACKS POWER. THESE ARE UNAPPROVED WIRING METHODS AND WORK WITH NO PERMITS AND INSPECTIONS.

DUE TO THE TAMPERING WITH THE GROUNDING ELECTRODE CONDUCTOR THAT LACKS IN THE DISCONNECT ENCLOSURE AND THE OTHER GROUNDING ELECTRODE CONDUCTOR THAT WAS CUT AND MODIFYING A NEW GROUNDING PATH FOR THE DISCONNECT WITHOUT PERMITS PLUS ALL THE NEW UNAPPROVED WORK THE FIRE CALL FOR ELECTRICAL BURNING SMELL WAS ALSO TAKEN IN CONSIDERATION, THE ONSITE INSPECTION REVEALED THAT THE 30 AMP BREAKER WHEN IN THE ON POSITION IT STARTED TO HUM / BUZZ THIS IS A RESULT OF MIS WIRING POSSIBLE OVER LOADED CIRCUIT. THIS SHOW THE WORK BEING DONE WAS NOT FROM A PROFESSIONAL ELECTRICAL CONTRACTOR. DURING THE INSPECTION A YOUNG GENTLEMEN SHOW UP AND ADMITTED TO ME HE HAD INSTALL 3 NEW CIRCUITS WITHOUT PERMITS BECAUSE HE WAS TOLD THE BOTTOM TWO BREAKER WERE DEFECTIVE. AFTER REVIEWING ALL DATA THE CITY OF TUCSON DID HAVE TEP CUT THE POWER FROM THE POLE. THE DWELLING WAS CONDEMNED UNFIT TO OCCUPY. THE PLACARD WAS POST AND A NOTICE AND ORDER WAS SIGNED BY THE TENANT. OWNER CONTACT WAS NOT MADE AFTER THREE ATTEMPTS.

THE PROPERTY DOES ISSUES WITH A TARP THE ROOF, TRASH AND DEBRIS. EXTERIOR WOOD ON THE DWELLING, STORAGE SHED WITH LACK OF PAINT PROTECTION.